Bindplane

The Bindplane Developer Hub

Welcome to the Bindplane developer hub. You'll find comprehensive guides and documentation to help you start working with Bindplane as quickly as possible, as well as support if you get stuck. Let's jump right in!

HPE Compute

Monitor HPE Compute Blade and Rack Server

Data Collection Setup

Metrics are collected via HPE iLO REST API.

Network Requirements

Port: 443 (TCP) for connection to the HPE iLO REST API.

Least Privileged User

The least-privileged iLO user account must be assigned the Login privilege.

Creating the LPU via the iLo GUI

  1. Log in to your HPE iLO 5 console as an administrator, then navigate to Administration -> User Administration, and select New.
  1. In the window that appears, enter your username and password information, and ensure the Login User Privilege is selected.
  2. Click Add User to save your settings.

Creating the LPU User Via CLI

To create your iLO user with "Login" User Privileges from the command-line interface:

Log in to your iLO as an administrator.
Run the following commands:

create /map1/accounts1 username=<username> password=<password>

Supported Versions

  • HPE ProLiant Servers: Gen 8, 9, or 10 (Blade or Rack)
  • iLO 4 with firmware 2.0+
  • iLO 5 with firmware 1.20+required connection method for rack server environments.

Connection Parameters

Name

Required?

Description

Host

Required

iLO hostname (or IP address), comma-separated list of hosts, or host IP range written in CIDR notation.

Port

The port for communication to the HP Compute chassis or rack server.

Username

Required

Password

Required

SSL Configuration

The SSL mode to use when connecting to the target. Can be configured to not use SSL (No SSL), use SSL but do not verify the target's certificate (No Verify), and use SSL and verify the target's certificate (Verify).

Connection Timeout (seconds)

The number of seconds to allow for connecting to the target.


Metrics

Blade

Name

Description

Asset Tag

A user-definable tag that is used to track this system for inventory or other client purposes.

BIOS Version

The BIOS Version of the System.

Health

The Health of the System.

Manufacturer

The Manufacturer of the System.

Memory Health

This represents the health state of the memory in the absence of its dependent resources.

Model

The Model of the System.

Network Adapter Health Critical (%)

The Network Adapter Health Critical of the System.

Network Adapter Health OK (%)

The Network Adapter Health OK of the System.

Network Adapter Health Warning (%)

The Network Adapter Health Warning of the System.

Platform Definition Firmware Version

The Platform Definition Firmware Version of the System.

Power Capacity (Watts)

The Power Capacity of the System.

Power Management Controller Boot Loader Firmware Version

The Power Management Controller Bootloader Firmware Version of the System.

Power Management Controller Firmware Version

The Power Management Controller Firmware Version of the System.

Power State

The Power State of the System.

Processor Count

The Processor Count of the System.

Processor Health

The Processor Health of the System.

Processor Model

The Processor Model of the System.

SAS PLD Firmware Version

The SAS PLD Firmware Version of the System.

Serial Number

The Serial Number of the System.

SKU

The SKU of the System.

SPS Firmware Version

The SPS Firmware Version of the System.

State

The State of the System.

System PLD Firmware Version

The System PLD Firmware Version of the System.

Total Memory (Gigabytes)

The Total Memory of the System.

UUID

The UUID of the System.

Chassis

Name

Description

Asset Tag

The Asset Tag of the Chassis.

Average CPU Temperature (Celsius)

The Average CPU Temperature of the Chassis.

Average Memory Temperature (Celsius)

The Average Memory Temperature of the Chassis.

Average Power Consumed (Watts)

The Average Power Consumed of the Chassis.

Bay Number

The Bay Number of the Chassis.

Bays Consumed Height

The Bays Consumed Height of the Chassis.

Bays Consumed Width

The Bays Consumed Width of the Chassis.

Fans Health Critical (%)

The Fans Health Critical of the Chassis.

Fans Health OK (%)

The Fans Health OK of the Chassis.

Fans Health Warning (%)

The Fans Health Warning of the Chassis.

Health

The Health of the Chassis.

Manufacturer

The Manufacturer of the Chassis.

Maximum CPU Temperature (Celsius)

The Maximum CPU Temperature of the Chassis.

Maximum Memory Temperature (Celsius)

The Maximum Memory Temperature of the Chassis.

Maximum Power Consumed (Watts)

The Maximum Power Consumed of the Chassis.

Minimum Power Consumed (Watts)

The Minimum Power Consumed of the Chassis.

Model

The Model of the Chassis.

Name

The name of the chassis.

Platform Definition Firmware Version

The Platform Definition Firmware Version of the Chassis.

Power Capacity (Watts)

The Power Capacity of the Chassis.

Power Consumed (Watts)

The Power Consumed of the Chassis.

Power Limit

The Power (Watts) limit (also known as Power Cap). Set to null to disable the power cap.

Power Management Controller Boot Loader Firmware Version

The Power Management Controller Boot Loader Firmware Version of the Chassis.

Power Management Controller Firmware Version

The Power Management Controller Firmware Version of the Chassis.

Power Management Hardware Family

The Power Management Hardware Family of the Chassis.

Power Metrics Interval (Minutes)

The Power Metrics Interval of the Chassis.

Power Supply Health Critical (%)

The Power Supply Health Critical of the Chassis.

Power Supply Health OK (%)

The Power Supply Health OK of the Chassis.

Power Supply Health Warning (%)

The Power Supply Health Warning of the Chassis.

Rack Part Number

The chassis rack part number.

Rack Product Description

The chassis rack product description.

SAS PLD Firmware Version

The SAS PLD Firmware Version of the Chassis.

Serial Number

The Serial Number of the Chassis.

SKU

The SKU of the Chassis.

SPS Firmware Version

The SPS Firmware Version of the Chassis.

State

The State of the Chassis.

System PLD Firmware Version

The System PLD Firmware Version of the Chassis.

Type

The Type of the Chassis.

U Height

The chassis rack U height.

U Location

The chassis rack U location.

U Position

The chassis U position in the rack.

UUID

The chassis UUID.

Enclosure

Name

Description

Name

The Name of the Enclosure.

UUID

The UUID of the Enclosure.

Fan

Name

Description

Chassis Serial Number

The Chassis Serial Number of the Fan.

Current Reading

The current speed of the fan.

Current Speed (Rotations per Minute)

The Current Speed of the Fan.

Current Units

Units for the CurrentReading.

Current Utilization

The current utilization (percent of max speed) of the fan.

Health

The Health of the Fan.

Location

The Location of the Fan.

Name

The Name of the Fan.

State

The State of the Fan.

Network Adapter

Name

Description

Bad Receives (Frames)

The Bad Receives of the Network Adapter.

Bad Transmits (Frames)

The Bad Transmits of the Network Adapter.

Chassis Serial Number

The Chassis Serial Number of the Network Adapter.

Firmware Version

The Firmware Version of the Network Adapter.

Good Receives (Frames)

The Good Receives of the Network Adapter.

Good Transmits (Frames)

The Good Transmits of the Network Adapter.

Health

The Health of the Network Adapter.

Part Number

The Part Number of the Network Adapter.

Port Health Critical (%)

The Port Health Critical of the Network Adapter.

Port Health OK (%)

The Port Health OK of the Network Adapter.

Port Health Warning (%)

The Port Health Warning of the Network Adapter.

Serial Number

The Serial Number of the Network Adapter.

State

The State of the Network Adapter.

Port

Name

Description

Bad Receives (Frames)

The Bad Receives of the Port.

Bad Transmits (Frames)

The Bad Transmits of the Port.

Full Duplex

The Full Duplex of the Port.

Good Receives (Frames)

The Good Receives of the Port.

Good Transmits (Frames)

The Good Transmits of the Port.

Health

The Health of the Port.

IPv4 Address

The IPv4 Address of the Port.

IPv6 Address

This is the IPv6 Address.

MAC Address

The MAC Address of the Port.

Network Adapter Serial Number

The Network Adapter Serial Number of the Port.

Speed (Megabytes per Second)

The Speed of the Port.

State

The State of the Port.

Power Supply

Name

Description

Average Power Output (Watts)

The Average Power Output of the Power Supply.

Bay Number

The Bay Number of the Power Supply.

Chassis Serial Number

The Chassis Serial Number of the Power Supply.

Firmware Version

The Firmware Version of the Power Supply.

Health

The Health of the Power Supply.

Hotplug Capable

The Hotplug Capable of the Power Supply.

Model

The Model of the Power Supply.

Power Capacity (Watts)

The Capacity of the Power Supply.

Serial Number

The Serial Number of the Power Supply.

Spare Part Number

The part number for this Power Supply

State

The State of the Power Supply.

Type

The Type of the Power Supply.

Rack

Name

Description

Asset Tag

The Asset Tag of the Rack.

Average CPU Temperature (Celsius)

The Average CPU Temperature of the Rack.

Average Memory Temperature (Celsius)

The Average Memory Temperature of the Rack.

Average Power Consumed (Watts)

The Average Power Consumed of the Rack.

Bay Number

The Bay Number of the Rack.

Bays Consumed Height

The Bays Consumed Height of the Rack.

Bays Consumed Width

The Bays Consumed Width of the Rack.

BIOS Version

The BIOS Version of the Rack.

Fans Health Critical (%)

The Fans Health Critical of the Rack.

Fans Health OK (%)

The Fans Health OK of the Rack.

Fans Health Warning (%)

The Fans Health Warning of the Rack.

Health

The Health of the Rack.

Manufacturer

The Manufacturer of the Rack.

Maximum CPU Temperature (Celsius)

The Maximum CPU Temperature of the Rack.

Maximum Memory Temperature (Celsius)

The Maximum Memory Temperature of the Rack.

Maximum Power Consumed (Watts)

The Maximum Power Consumed of the Rack.

Memory Health

This represents the health state of the memory in the absence of its dependent resources.

Minimum Power Consumed (Watts)

The Minimum Power Consumed of the Rack.

Model

The Model of the Rack.

Network Adapter Health Critical (%)

The Network Adapter Health Critical of the Rack.

Network Adapter Health OK (%)

The Network Adapter Health OK of the Rack.

Network Adapter Health Warning (%)

The Network Adapter Health Warning of the Rack.

Platform Definition Firmware Version

The Platform Definition Firmware Version of the Rack.

Power Capacity (Watts)

The Power Capacity of the Rack.

Power Consumed (Watts)

The Power Consumed of the Rack.

Power Management Controller Boot Loader Firmware Version

The Power Management Controller Boot Loader Firmware Version of the Rack.

Power Management Controller Firmware Version

The Power Management Controller Firmware Version of the Rack.

Power Management Hardware Family

The Power Management Hardware Family of the Rack.

Power Metrics Interval (Minutes)

The Power Metrics Interval of the Rack.

Power State

The Power State of the Rack.

Power Supply Health Critical (%)

The Power Supply Health Critical of the Rack.

Power Supply Health OK (%)

The Power Supply Health OK of the Rack.

Power Supply Health Warning (%)

The Power Supply Health Warning of the Rack.

Processor Count

The Processor Count of the Rack.

Processor Health

The Processor Health of the Rack.

Processor Model

The Processor Model of the Rack.

SAS PLD Firmware Version

The SAS PLD Firmware Version of the Rack.

Serial Number

The Serial Number of the Rack.

SKU

The SKU of the Rack.

SPS Firmware Version

The SPS Firmware Version of the Rack.

State

The State of the Rack.

System PLD Firmware Version

The System PLD Firmware Version of the Rack.

Total Memory (Gigabytes)

The Total Memory of the Rack.

Type

The Type of the Rack.

System

Name

Description

Asset Tag

A user-definable tag that is used to track this system for inventory or other client purposes.

BIOS Version

The BIOS Version of the System.

Health

The Health of the System.

Manufacturer

The Manufacturer of the System.

Memory Health

This represents the health state of the memory in the absence of its dependent resources.

Model

The Model of the System.

Network Adapter Health Critical (%)

The Network Adapter Health Critical of the System.

Network Adapter Health OK (%)

The Network Adapter Health OK of the System.

Network Adapter Health Warning (%)

The Network Adapter Health Warning of the System.

Platform Definition Firmware Version

The Platform Definition Firmware Version of the System.

Power Capacity (Watts)

The Power Capacity of the System.

Power Management Controller Boot Loader Firmware Version

The Power Management Controller Bootloader Firmware Version of the System.

Power Management Controller Firmware Version

The Power Management Controller Firmware Version of the System.

Power State

The Power State of the System.

Processor Count

The Processor Count of the System.

Processor Health

The Processor Health of the System.

Processor Model

The Processor Model of the System.

SAS PLD Firmware Version

The SAS PLD Firmware Version of the System.

Serial Number

The Serial Number of the System.

SKU

The SKU of the System.

SPS Firmware Version

The SPS Firmware Version of the System.

State

The State of the System.

System PLD Firmware Version

The System PLD Firmware Version of the System.

Total Memory (Gigabytes)

The Total Memory of the System.

UUID

The UUID of the System.

Updated about a year ago

HPE Compute


Monitor HPE Compute Blade and Rack Server

Suggested Edits are limited on API Reference Pages

You can only suggest edits to Markdown body content, but not to the API spec.