Bindplane

The Bindplane Developer Hub

Welcome to the Bindplane developer hub. You'll find comprehensive guides and documentation to help you start working with Bindplane as quickly as possible, as well as support if you get stuck. Let's jump right in!

Dell EMC XtremIO

Connection Parameters

Name
Required?
Description

Host

Required

The EMC XtremeIO Management Server to connect to.

Port

The port for communication to the EMC XtremeIO Management Server.

Username

Required

Password

Required

Protocol

Request Timeout (seconds)

The number of seconds to allow for the API to return a response.

Ssl_key_store_path

Path to the SSL Key Store. Default: Trust all certificates.

Collect Events

Controls whether events are collected and returned.

Max Events

The maximum number of events to collect.

Event Cutoff Time

Events before this time will not be collected.

Minimum Event Severity

Events with a severity level below this minimum will not be returned.

Metrics

Battery Backup Unit

Name
Description

Accumulated Daily Uptime (Minutes)

Accumulated daily uptime of the battery backup unit.

Average Daily Temperature (Celsius)

Average daily temperature of the battery backup unit.

Battery Runtime (Minutes)

Runtime of the battery backup unit.

Battery Voltage (Volts)

Battery voltage.

Cluster GUID

The cluster GUID of the battery backup unit.

Enabled State

Indicates whether the battery backup unit is currently enabled or disabled, either by the user or the cluster.

Firmware Version

Current firmware version of the BBU.

Firmware Version Error

Firmware version error (if any) of the battery backup unit.

FRU Lifecycle State

FRU lifecycle state of the battery backup unit.

FRU Replace Failure Reason

The reason (if any) for the FRU replace failure.

GUID

The GUID of the battery backup unit.

Hardware Revision

Hardware level of the power supply unit.

Identify LED

Identify LED for the battery backup unit.

Index

Index of the battery backup unit.

Index In Brick

The BBU's index within the X-Brick, either 1 or 2. Always 1 for multiple X-Brick clusters (for all X-Bricks), but two BBUs are available for a single X-Brick cluster.

Input Frequency (Hertz)

Input frequency of the battery backup unit.

Is Bypass Active

Whether or not the bypass is active for the battery backup unit.

Is Low Battery Has Input

Whether or not the low battery has input.

Is Low Battery No Input

Whether or not the low battery has no input.

Is Low Battery Runtime

Whether or not there is low battery runtime.

Is UPS Overload

Whether or not the UPS is overloaded.

Model Name

Model name for the BBU.

Object Severity

Object severity of the battery backup unit.

Outlet 1 Status

Outlet 1 status for the battery backup unit.

Outlet 2 Status

Outlet 2 status of the battery backup unit.

Output Current (Amperes)

Output current of the battery backup unit.

Output Frequency (Hertz)

Output frequency of the battery backup unit.

Output Voltage (Volts)

Output voltage of the battery backup unit.

Part Number

Part number. An EMC-assigned string identifying part (SKU).

Power (Volts)

Power of the battery backup unit.

Power Feed

A and B PSU power feeds.

Real Power (Volts)

Real power of the battery backup unit.

Serial Number

Serial number of the battery backup unit.

Status LED

Status LED for the battery backup unit.

UPS Alarm

UPS alarm of the battery backup unit.

UPS Battery Charge (%)

Battery charge of the UPS in percentage.

UPS Battery Uncharged (%)

Percentage of the UPS battery not charged.

UPS Connection State

The state of the UPS connection.

UPS Input

UPS input.

UPS Load (%)

UPS load in percentage.

UPS Load Percent Level

The load percent level of the UPS.

UPS Need Battery Replacement

Whether or not the UPS needs a battery replacement.

UPS Status

The status of the UPS.

UPS Voltage (Volts)

UPS voltage of the battery backup unit.

X-Brick GUID

The X-Brick GUID of the battery backup unit.

Cluster

Name
Description

128KB Average Latency (Microseconds)

Average Latency 128KB

128KB IO Rate (Operations per Second)

IO Rate 128KB

128KB Read IO Rate (Operations per Second)

Read IO Rate 128KB

128KB Read Latency (Microseconds)

Read Latency 128KB

128KB Read Throughput (Kilobytes per Second)

Read Throughput 128KB

128KB Throughput (Kilobytes per Second)

Throughput 128KB

128KB Write IO Rate (Operations per Second)

Write IO Rate 128KB

128KB Write Latency (Microseconds)

Write Latency 128KB

128KB Write Throughput (Kilobytes per Second)

Write throughput for 128KB block size.

16KB Average Latency (Microseconds)

Average Latency 16KB

16KB IO Rate (Operations per Second)

IO Rate 16KB

16KB Read IO Rate (Operations per Second)

Read IO Rate 16KB

16KB Read Latency (Microseconds)

Read Latency 16KB

16KB Read Throughput (Kilobytes per Second)

Read Throughput 16KB

16KB Throughput (Kilobytes per Second)

Throughput 16KB

16KB Write IO Rate (Operations per Second)

Write IO Rate 16KB

16KB Write Latency (Microseconds)

Write Latency 16KB

16KB Write Throughput (Kilobytes per Second)

Write Throughput 16KB

1KB Average Latency (Microseconds)

Average Latency 1KB

1KB IO Rate (Operations per Second)

IO Rate 1KB

1KB Read IO Rate (Operations per Second)

Read IO Rate 1KB

1KB Read Latency (Microseconds)

Read Latency 1KB

1KB Read Throughput (Kilobytes per Second)

Read Throughput 1KB

1KB Throughput (Kilobytes per Second)

Throughput 1KB

1KB Write IO Rate (Operations per Second)

Write IO Rate 1KB

1KB Write Latency (Microseconds)

Write Latency 1KB

1KB Write Throughput (Kilobytes per Second)

Write Throughput 1KB

1MB Average Latency (Microseconds)

Average Latency 1MB

1MB IO Rate (Operations per Second)

IO Rate 1MB

1MB Read IO Rate (Operations per Second)

Read IO Rate 1MB

1MB Read Latency (Microseconds)

Read Latency 1MB

1MB Read Throughput (Kilobytes per Second)

Read Throughput 1MB

1MB Throughput (Kilobytes per Second)

Throughput 1MB

1MB Write IO Rate (Operations per Second)

Write IO Rate 1MB

1MB Write Latency (Microseconds)

Write Latency 1MB

1MB Write Throughput (Kilobytes per Second)

Write Throughput 1MB

256KB Average Latency (Microseconds)

Average Latency 256KB

256KB IO Rate (Operations per Second)

IO Rate 256KB

256KB Read IO Rate (Operations per Second)

Read IO Rate 256KB

256KB Read Latency (Microseconds)

Read Latency 256KB

256KB Read Throughput (Kilobytes per Second)

Read Throughput 256KB

256KB Throughput (Kilobytes per Second)

Throughput 256KB

256KB Write IO Rate (Operations per Second)

Write IO Rate 256KB

256KB Write Latency (Microseconds)

Write Latency 256KB

256KB Write Throughput (Kilobytes per Second)

Write Throughput 256KB

2KB Average Latency (Microseconds)

Average latency for 2KB block size.

2KB IO Rate (Operations per Second)

IO Rate 2KB

2KB Read IO Rate (Operations per Second)

Read IO Rate 2KB

2KB Read Latency (Microseconds)

Read Latency 2KB

2KB Read Throughput (Kilobytes per Second)

Read Throughput 2KB

2KB Throughput (Kilobytes per Second)

Throughput 2KB

2KB Write IO Rate (Operations per Second)

Write IO Rate 2KB

2KB Write Latency (Microseconds)

Write Latency 2KB

2KB Write Throughput (Kilobytes per Second)

Write Throughput 2KB

32KB Average Latency (Microseconds)

Average Latency 32KB

32KB IO Rate (Operations per Second)

IO Rate 32KB

32KB Read IO Rate (Operations per Second)

Read IO Rate 32KB

32KB Read Latency (Microseconds)

Average read latency for 32KB block size.

32KB Read Throughput (Kilobytes per Second)

Read Throughput 32KB

32KB Throughput (Kilobytes per Second)

Throughput 32KB

32KB Write IO Rate (Operations per Second)

Write IO Rate 32KB

32KB Write Latency (Microseconds)

Write Latency 32KB

32KB Write Throughput (Kilobytes per Second)

Write Throughput 32KB

4KB Average Latency (Microseconds)

Average Latency 4KB

4KB IO Rate (Operations per Second)

IO Rate 4KB

4KB Read IO Rate (Operations per Second)

Read IO Rate 4KB

4KB Read Latency (Microseconds)

Read Latency 4KB

4KB Read Throughput (Kilobytes per Second)

Read Throughput 4KB

4KB Throughput (Kilobytes per Second)

Throughput 4KB

4KB Write IO Rate (Operations per Second)

Write IO Rate 4KB

4KB Write Latency (Microseconds)

Write Latency 4KB

4KB Write Throughput (Kilobytes per Second)

Write Throughput 4KB

512B Average Latency (Microseconds)

Average latency for 512B block size.

512B IO Rate (Operations per Second)

IO Rate 512B

512B Read IO Rate (Operations per Second)

Read IO Rate 512B

512B Read Latency (Microseconds)

Read Latency 512B

512B Read Throughput (Kilobytes per Second)

Read Throughput 512B

512B Throughput (Kilobytes per Second)

Throughput 512B

512B Write IO Rate (Operations per Second)

Write IO Rate 512B

512B Write Latency (Microseconds)

Write Latency 512B

512B Write Throughput (Kilobytes per Second)

Write throughput for 512B block size.

512KB Average Latency (Microseconds)

Average Latency 512KB

512KB IO Rate (Operations per Second)

IO Rate 512KB

512KB Read IO Rate (Operations per Second)

Read IO Rate 512KB

512KB Read Latency (Microseconds)

Read Latency 512KB

512KB Read Throughput (Kilobytes per Second)

Read Throughput 512KB

512KB Throughput (Kilobytes per Second)

Throughput 512KB

512KB Write IO Rate (Operations per Second)

Write IO Rate 512KB

512KB Write Latency (Microseconds)

Write Latency 512KB

512KB Write Throughput (Kilobytes per Second)

Write throughput for 512KB block size.

64KB Average Latency (Microseconds)

Average Latency 64KB

64KB IO Rate (Operations per Second)

IO Rate 64KB

64KB Read IO Rate (Operations per Second)

Read IO Rate 64KB

64KB Read Latency (Microseconds)

Read Latency 64KB

64KB Read Throughput (Kilobytes per Second)

Read Throughput 64KB

64KB Throughput (Kilobytes per Second)

Throughput 64KB

64KB Write IO Rate (Operations per Second)

Write IO Rate 64KB

64KB Write Latency (Microseconds)

Write Latency 64KB

64KB Write Throughput (Kilobytes per Second)

Write throughput for 64KB block size.

8KB Average Latency (Microseconds)

Average Latency 8KB

8KB IO Rate (Operations per Second)

IO Rate 8KB

8KB Read IO Rate (Operations per Second)

Read IO Rate 8KB

8KB Read Latency (Microseconds)

Read Latency 8KB

8KB Read Throughput (Kilobytes per Second)

Read Throughput 8KB

8KB Throughput (Kilobytes per Second)

Throughput 8KB

8KB Write IO Rate (Operations per Second)

Write IO Rate 8KB

8KB Write Latency (Microseconds)

Write Latency 8KB

8KB Write Throughput (Kilobytes per Second)

Write Throughput 8KB

Average Latency (Microseconds)

Average Latency

Average Latency Greater Than 1MB (Microseconds)

Average latency greater than 1MB for the cluster.

CHAP Authentication Mode

Describes the CHAP mode for Initiator discovery (applicable for iSCSI only).

CHAP Discovery Mode

Describes the CHAP mode for Initiator discovery (applicable for iSCSI only).

Compression Factor

Compression factor for the cluster

Compression Factor (Text)

Text representation of the cluster's compression factor.

Compression Mode

Compression mode.

Configurable Volume Type Capability

Denotes whether the cluster supports the capability to configure a Volume's vol-access.

Consistency State

Consistency state of the cluster.

Critical Alert Count

Number of critical alerts on the cluster.

DAE Count

Number of DAEs.

Data Reduction Ratio

Data reduction ratio of the cluster.

Data Reduction Ratio (Text)

Text representation of the cluster's data reduction ratio.

Debug Create Timeout

Debug Create Timeout for the cluster.

Deduplication Ratio

The deduplication ratio of the cluster.

Deduplication Ratio (Text)

The text representation of the deduplication ratio of the cluster.

Deduplication Space In Use (Tebibytes)

Deduplication space in use by the cluster.

DPG Count

The number of DPGs.

Encryption Mode

Controls whether encryption (Data at Rest) is performed for all cluster SSDs, DAE SSDs and Local Disks.

Encryption Supported

The capability parameter reflects whether Data at Rest encryption is possible for this cluster.

Expansion In Progress

Whether or not a cluster expansion is in progress.

FC Port Speed

FC port speed.

Free Logical Space In Base 10 (Terabytes)

Free logical space in base 10

Free Physical Space (%)

Percentage of physical space that is free.

Free Physical Space In Base 10 (Terabytes)

Free physical space in base 10.

Free Physical Space Level

Free physical space level of the cluster.

GUID

The GUID of the cluster.

IB Switch Count

Number of IB switches

Index

Index of the cluster.

Internal Volume Count

Number of internal volumes.

IO Rate (Operations per Second)

IO Rate

IO Rate By Block (Operations per Second)

IO Rate by block for the cluster.

IO Rate Greater Than 1MB (Operations per Second)

IO Rate greater than 1MB for the cluster.

Is Any C Module Lazy Load In Progress

Whether or not any C module lazy load is in progress.

Is Any D Module Lazy Load In Progress

Whether or not any D module lazy load is in progress.

Last Upgrade Attempt Timestamp

Timestamp of last upgrade attempt.

Last Upgrade Attempt Version

Version of the last upgrade attempt.

License ID

Cluster's license index number.

Logical Size In Base 10 (Terabytes)

Logical Size In Base 10

Logical Space (Tebibytes)

Total logical space for the cluster.

Logical Space In Use (Tebibytes)

Logical space in use by the cluster.

Logical Space In Use In Base 10 (Terabytes)

Logical space in use in base 10.

Major Alert Count

Number of major alerts on the cluster.

Maximum Data Transfer Done (%)

The percentage of the maximum data transfer done.

Maximum SSD Count per DPG

The maximum number of SSDs a DPG can contain.

Memory Recovery Status

Memory recovery status of the cluster.

Memory Utilization (%)

Percentage of total memory that is in use by the cluster.

Minor Alert Count

Number of minor alerts on the cluster.

Mode Switch Status

Status of the cluster mode switch.

NAA System ID

A Volume's SCSI NAA name consisting of three elements.

Node Count

Number of nodes for the cluster.

Obfuscate Debug

Determines whether debug information is created while obfuscating IP addresses. Default is disabled. Debug information is placed in the log bundle.

Object Severity

Object severity.

OS Upgrade In Progress

Whether or not an OS upgrade is in progress on the cluster.

Physical Space (Tebibytes)

Physical space for the cluster.

Physical Space In Base 10 (Terabytes)

Physical space in base 10.

Physical Space In Use (Tebibytes)

Physical space in use on the cluster.

Physical Space In Use In Base 10 (Terabytes)

Physical space in use in base 10.

Physical Space per SSD (Gibibytes)

Physical space per SSD for the cluster.

PSNT Part Number

PSNT part number.

Read IO Rate (Operations per Second)

Read IO Rate

Read IO Rate By Block (Operations per Second)

Read IO Rate By Block

Read IO Rate Greater Than 1MB (Operations per Second)

Read IO Rate Greater Than 1MB

Read Latency (Microseconds)

Read Latency

Read Latency Greater Than 1MB (Microseconds)

Read Latency Greater Than 1MB

Read Throughput (Kilobytes per Second)

Read Throughput

Read Throughput By Block (Kilobytes per Second)

Read Throughput By Block

Read Throughput Greater Than 1MB (Kilobytes per Second)

Read Throughput Greater Than 1MB

Read / Write Ratio

The ratio of read to write IOPS.

SC Front Panel Temperature Monitor Mode

Storage Controller front panel temperature monitor mode (the parameter used to disable the feature if the front panel sensor is faulty).

Shared Memory (Gibibytes)

Shared memory of the cluster.

Shared Memory In Use (Gibibytes)

Shared Memory In Use

Shared Memory In Use Ratio Level

Shared memory in use ratio level of the cluster.

Shared Memory In Use Recoverable Ratio Level

Shared memory in use recoverable ratio level of the cluster.

Size and Capacity

The size and capacity of the cluster.

Small IO Rate (Operations per Second)

Small IO Rate

Small Read IO Rate (Operations per Second)

Small Read IO Rate

Small Read Throughput (Kilobytes per Second)

Small Read Throughput

Small Throughput (Kilobytes per Second)

Small Throughput

Small Write IO Rate (Operations per Second)

Small Write IO Rate

Small Write Throughput (Kilobytes per Second)

Small Write Throughput

Space In Use (Tebibytes)

Space in use by the cluster.

Space Saving Ratio

The space saving ratio of the cluster.

SSD Count

Number of SSDs.

SSD High Utilization Threshold Crossing

SSD high utilization threshold crossing of the cluster.

SSD Very High Utilization Threshold Crossing

SSD very high utilization threshold crossing of the cluster.

SSH Firewall Mode

SSH Firewall Mode

Stopped Reason

Reason for stoppage.

System Activation Timestamp

Cluster's activation uptime timestamp as of 1.1.1970, measured in seconds.

System Health State

Health state of the system.

System Manager Connection Error Reason

Reason for the system manager connection error.

System Manager Connection State

State of the system manager connection.

System PSNT Serial Number

Cluster's Product Serial Number tag (PSNT) serial number.

System Software Version

XIOS version.

System Start Timestamp

Timestamp of the cluster's commencement.

System State

State of the system.

System Stop Type

System stop type of the cluster.

Target Port Count

Total number of the cluster's target ports

Thin Provisioning Ratio

The thin provisioning ratio of the cluster.

Thin Provisioning Savings (%)

Thin provisioning savings for the cluster.

Throughput (Kilobytes per Second)

Throughput

Throughput By Block (Kilobytes per Second)

Throughput By Block

Throughput Greater Than 1MB (Kilobytes per Second)

Throughput Greater Than 1MB

Total Memory In Use (Gibibytes)

Total memory in use by the cluster.

Unaligned IO Rate (Operations per Second)

Unaligned IO Rate

Unaligned Read IO Rate (Operations per Second)

Unaligned Read IO Rate

Unaligned Read Throughput (Kilobytes per Second)

Unaligned Read Throughput

Unaligned Throughput (Kilobytes per Second)

Unaligned Throughput

Unaligned Write IO Rate (Operations per Second)

Unaligned Write IO Rate

Unaligned Write Throughput (Kilobytes per Second)

Unaligned Write Throughput

Under Maintenance

Whether or not the cluster is under maintenance.

Upgrade Failure Reason

Reason for the upgrade failure (if any).

Upgrade State

Upgrade state of the cluster.

UPS Count

Total number of the cluster's BBUs.

VAAI Thin Provisioning Limit Crossing

VAAI thin provisioning limit crossing of the cluster.

Volume Count

Total number of the cluster's provisioned Volumes.

Write IO Rate (Operations per Second)

Write IO Rate

Write IO Rate By Block (Operations per Second)

Write IO Rate By Block

Write IO Rate Greater Than 1MB (Operations per Second)

Write IO Rate Greater Than 1MB

Write Latency (Microseconds)

Write Latency

Write Latency Greater Than 1MB (Microseconds)

Write Latency Greater Than 1MB

Write Throughput (Kilobytes per Second)

Write Throughput

Write Throughput By Block (Kilobytes per Second)

Write Throughput By Block

Write Throughput Greater Than 1MB (Kilobytes per Second)

Write Throughput Greater Than 1MB

X-Brick Count

Total number of X-Bricks for the cluster.

XEnv Count

Number of XEnvs for the cluster.

XMS GUID

GUID of the cluster's XMS.

Data Protection Group

Name
Description

128KB Read IO Rate (Operations per Second)

Read IO Rate for 128KB reads.

128KB Read Throughput (Kilobytes per Second)

Read throughput for 128KB reads.

128KB Write IO Rate (Operations per Second)

Write IO Rate for 128KB writes.

128KB Write Throughput (Kilobytes per Second)

Write throughput for 128KB writes.

16KB Read IO Rate (Operations per Second)

Read IO Rate for 16KB reads.

16KB Read Throughput (Kilobytes per Second)

Read throughput for 16KB reads.

16KB Write IO Rate (Operations per Second)

Write IO Rate for 16KB writes.

16KB Write Throughput (Kilobytes per Second)

Write throughput for 16KB writes.

1KB Read IO Rate (Operations per Second)

Read IO Rate for 1KB reads.

1KB Read Throughput (Kilobytes per Second)

Read throughput for 1KB reads.

1KB Write IO Rate (Operations per Second)

Write IO Rate for 1KB writes.

1KB Write Throughput (Kilobytes per Second)

Write throughput for 1KB writes.

256KB Read IO Rate (Operations per Second)

Read IO Rate for 256KB reads.

256KB Read Throughput (Kilobytes per Second)

Read throughput for 256KB reads.

256KB Write IO Rate (Operations per Second)

Write IO Rate for 256KB writes.

256KB Write Throughput (Kilobytes per Second)

Write throughput for 256KB writes.

2KB Read IO Rate (Operations per Second)

Read IO Rate for 2KB reads.

2KB Read Throughput (Kilobytes per Second)

Read throughput for 2KB reads.

2KB Write IO Rate (Operations per Second)

Write IO Rate for 2KB writes.

2KB Write Throughput (Kilobytes per Second)

Write throughput for 2KB writes.

32KB Read IO Rate (Operations per Second)

Read IO Rate for 32KB reads.

32KB Read Throughput (Kilobytes per Second)

Read throughput for 32KB reads.

32KB Write IO Rate (Operations per Second)

Write IO Rate for 32KB writes.

32KB Write Throughput (Kilobytes per Second)

Write throughput for 32KB writes.

4KB Read IO Rate (Operations per Second)

Read IO Rate for 4KB reads.

4KB Read Throughput (Kilobytes per Second)

Read throughput for 4KB reads.

4KB Write IO Rate (Operations per Second)

Write IO Rate for 4KB writes.

4KB Write Throughput (Kilobytes per Second)

Write throughput for 4KB writes.

512B Read IO Rate (Operations per Second)

Read IO Rate for 512B reads.

512B Read Throughput (Kilobytes per Second)

Read throughput for 512B reads.

512B Write IO Rate (Operations per Second)

Write IO Rate for 512B writes.

512B Write Throughput (Kilobytes per Second)

Write throughput for 512B writes.

512KB Read IO Rate (Operations per Second)

Read IO Rate for 512KB reads.

512KB Read Throughput (Kilobytes per Second)

Read throughput for 512KB reads.

512KB Write IO Rate (Operations per Second)

Write IO Rate for 512KB writes.

512KB Write Throughput (Kilobytes per Second)

Write throughput for __ writes.

64KB Read IO Rate (Operations per Second)

Read IO Rate for 64KB reads.

64KB Read Throughput (Kilobytes per Second)

Read throughput for 64KB reads.

64KB Write IO Rate (Operations per Second)

Write IO Rate for 64KB writes.

64KB Write Throughput (Kilobytes per Second)

Write throughput for 64KB writes.

8KB Read IO Rate (Operations per Second)

Read IO Rate for 8KB reads.

8KB Read Throughput (Kilobytes per Second)

Read throughput for 8KB reads.

8KB Write IO Rate (Operations per Second)

Write IO Rate for 8KB writes.

8KB Write Throughput (Kilobytes per Second)

Write throughput for 8KB writes.

Available Rebuilds

Number of available rebuilds the DPG can currently perform.

Cluster GUID

GUID for the related Cluster resource.

GUID

The GUID of the DPG.

Index

DPG's index number as defined by the XMS upon its creation (a unique positive number).

Integrating Slot Number

Slot currently undergoing processing. The value is 0 when no specific Slot is undergoing processing.

IO Rate (Operations per Second)

IO Rate

Node Count

DPG's total number of Storage Controllers.

Object Severity

DPG's severity, based on severity level of current Alerts (Alerts still uncleared) for this DPG. Possible values are 'clear', 'information', 'minor', 'major', or 'critical'.

Physical Free Space (%)

DPG's percentage of free physical space.

Physical Space (Tebibytes)

Total physical space on the SSDs.

Physical Space In Use (Tebibytes)

Reports how much of physical space of the DPG is currently in use.

Physical Space Levels

DPG physical space levels. Events are triggered for any change in this parameter.

Proactive Metadata Loading

This Boolean property reflects whether the cluster performs proactive loading of the metadata (property returns true). This may happen after the cluster is started or recovers from an extreme situation. At this stage, there may be performance degradation.

Protection State

DPG's protection state. If the DPG is currently under initial configuration, the parameter is initializing.

Read IO Rate (Operations per Second)

Read IO Rate.

Read IO Rate 1MB (Operations per Second)

Read IO Rate for 1MB reads.

Read IO Rate By Block (Operations per Second)

Read IO Rate for block reads.

Read IO Rate Greater Than 1MB (Operations per Second)

Read IO Rate for reads greater than one megabyte.

Read Throughput (Kilobytes per Second)

Read Throughput

Read Throughput 1MB (Kilobytes per Second)

Read throughput for 1MB reads.

Read Throughput By Block (Kilobytes per Second)

Read throughput for block reads.

Read Throughput Greater Than 1MB (Kilobytes per Second)

Read throughput for reads greater than a megabyte.

Read / Write Ratio

The ratio of read to write IO Rate.

Rebalance Progress (%)

Shows the progress of a DPG rebalance.

Rebuild In Progress

Indicates if the DPG currently performs a rebuild, and its progress.

Rebuild Prevention Reason

When an DPG enters a degraded state (either single or dual failure), a rebuild is generally initiated. However, conditions may prevent the rebuild. The parameter includes the reason for rebuild prevention.

Rebuild Progress (%)

The rebuild progress status.

SSD Count

DPG's total number of the SSDs.

SSD Preparation In Progress

The current state of the SSD preparation.

SSD Preparation Progress (%)

Indicates if the DPG is currently performing an SSD preparation, and its progress.

SSD Size (Tebibytes)

DPG's overall size of unfailed SSDs.

Throughput (Kilobytes per Second)

Total Throughput(read + write)

Useful SSD Space (Tebibytes)

DPG's total amount of useful SSD space over all unfailed SSDs, for this DPG.

Write IO Rate (Operations per Second)

Write IO Rate.

Write IO Rate 1MB (Operations per Second)

Write IO Rate for 1MB writes.

Write IO Rate By Block (Operations per Second)

Write IO Rate for block writes.

Write IO Rate Greater Than 1MB (Operations per Second)

Write IO Rate for writes grater than one megabyte.

Write Throughput (Kilobytes per Second)

Write throughput.

Write Throughput 1MB (Kilobytes per Second)

Write throughput for 1MB writes.

Write Throughput By Block (Kilobytes per Second)

Write throughput for block writes.

Write Throughput Greater Than 1MB (Kilobytes per Second)

Write throughput for writes greater than one megabyte.

X-Brick GUID

The GUID of the parent X-Brick.

Disk Array Enclosure

Name
Description

Cluster GUID

System ID of the disk array enclosure.

DAE Controller Count

Number of DAE controllers.

DAE PSU Count

Number of DAE PSUs.

Firmware Version

Firmware version of the disk array enclosure.

FRU Lifecycle State

FRU lifecycle state of the disk array enclosure.

FRU Replace Failure Reason

Reason (if any) for the FRU replace failure.

GUID

GUID of the disk array enclosure.

Hardware Revision

Hardware revision of the disk array enclosure.

Identify LED

Identify LED of the disk array enclosure.

Index

Index of the disk array enclosure.

Model Name

Model name of the disk array enclosure.

Object Severity

Object severity of the disk array enclosure.

Part Number

Part Number

Serial Number

Serial Number

Status LED

Status LED for the disk array enclosure.

X-Brick GUID

X-Brick GUID of the disk array enclosure.

Host Interface

Name
Description

Accumulated Read Operation Count (Operations)

Total accumulative number of read operations having occurred during the Target's lifespan.

Accumulated Size of Read Operation Count (Tebibytes)

Accumulative capacity KB size of read operations having occurred during the Target's lifespan.

Accumulated Size of Write Operation Count (Tebibytes)

Accumulative capacity KB size of write operations having occurred during the Target's lifespan.

Accumulated Small Read IO Operation Count (Operations)

Accumulated number small reads input/output operations for the Target.

Accumulated Small Write IO Operation Count (Operations)

Accumulated number of small writes input/output operations recursively held by this Target.

Accumulated Unaligned Read IO Operation Count (Operations)

Accumulated number of unaligned reads for input/output operations recursively contained by this Target.

Accumulated Unaligned Write IO Operation Count (Operations)

Accumulated number of unaligned writes for input/output operations recursively contained by this Target.

Accumulated Write Operation Count (Operations)

Accumulative number of write operations having occurred during the Target's lifespan.

Average Latency (Microseconds)

Average latency of read and write operations.

Certainty

Indicates confidence that the XMS and the cluster are synchronized. Value changes from OK if a request is sent but the XMS is unable to determine the success of the request.

Driver Version

Driver version of the Target object.

Ethernet Data Received (Kilobytes)

The total KBS received. Relevant for iSCSI only.

Ethernet Data Transmitted (Kilobytes)

The total number of KBS transmitted. Relevant for iSCSI only.

Ethernet Packet Received

The number of Ethernet packets received. Relevant for iSCSI only.

Ethernet Packets Transmitted

The number of Ethernet packets transmitted. Relevant for iSCSI only.

Fibre Channel Dumped Frames

The Fibre Channel ports' diagnostic counter for dumped frames. Impacts the port_health_level.

Fibre Channel Invalid CRC Count

The Fibre Channel ports' diagnostic counter for invalid CRC count. Impacts the port_health_level.

Fibre Channel Link Failure Count

The Fibre Channel ports' diagnostic counter for failure count. Impacts the port_health_level.

Fibre Channel Loss of Signal Count

The Fibre Channel ports' diagnostic counter for loss of signal count. Impacts the port_health_level.

Fibre Channel Loss of Sync Count

The Fibre Channel ports' diagnostic counter for loss of synchronized count. Impacts the port_health_level.

Fibre Channel Primary Sequential Protocol Error Count

The Fibre Channel ports' diagnostic counter for primary sequential protocol error count. Impacts the port-health-level.

Fibre Channel Sequential Retransmitted Request Count

The Fibre Channel ports' diagnostic counter for sequential retransmission request count. Values impact the port_health_level.

Firmware Version

Current firmware version of the Target.

GUID

GUID

Index

Index

IO Rate (Operations per Second)

Target's total read and write real-time input/output operations per second.

Jumbo Enabled

Determines whether jumbo frames are supported for this Target. The default value is false.

MTU

Maximum valid values for maximum transmission unit sizes are 1500 when non-jumbo frames are enabled and 9216 when jumbo frames are enabled for iSCSI Targets. Applicable for iSCSI only.

Object Severity

Target's severity, based on severity level of current Alerts (Alerts still uncleared) for this Target.

Port Address

Port Address

Port Health Level

Port Health Level

Port Index

Port Index

Port MAC Address

MAC address of this target port (relevant for iSCSI Targets only).

Port Speed

The negotiated speed of the port (some applicable for Ethernet and some for Fibre Channel).

Port State

State of the Target port (Fibre Channel or iSCSI).

Port Type

Port type (Fibre Channel or iSCSI) and port's address.

Read IO Rate (Operations per Second)

Total read real-time input/output operations per second.

Read Latency (Microseconds)

Real-time average latency of read operations.

Read Throughput (Kilobytes per Second)

Total read bandwidth in MB per second.

Read / Write Ratio

The ratio of read to write IOPS.

Relative Target Port

Indicates the relative Target port.

Small IO Rate (Operations per Second)

Current IOPS of small input/output operations per second, addressed at the Initiator Group.

Small Read IO Rate (Operations per Second)

Current IOPS of small read input/output operations per second, addressed at the Target.

Small Read Throughput (Kilobytes per Second)

Current bandwidth of small input/output operations, addressed at the Target.

Small Throughput (Kilobytes per Second)

Current bandwidth of small input/output operations, addressed at the Target.

Small Write IO Rate (Operations per Second)

Current IOPS of small write input/output operations per second, addressed at the Target.

Small Write Throughput (Kilobytes per Second)

Current bandwidth of small write input/output operations, addressed at the Target.

Storage Controller GUID

The GUID of the Storage Controller that this Host Interface is on.

System GUID

The GUID of the Cluster that this Host Interface is on.

Tar Error Reason

Failure type causing the Target's target_health_state not to be 'clear'.

Throughput (Kilobytes per Second)

Total read and write bandwidth.

Total CRC Error Ethernet Packets Received

The number of Ethernet frames received with CRC error (and thus dropped). Relevant for iSCSI only.

Total Dropped Ethernet Packets

The number of packets that failed to be transmitted due to error. Relevant for iSCSI only.

Total No Buffer Error Ethernet Packets Received

The number of Ethernet packets that failed to be received due to lack of buffer space. Relevant for iSCSI only.

Unaligned IO Rate (Operations per Second)

Current IOPS of unaligned input/output operations per second, addressed at the Target.

Unaligned Read IO Rate (Operations per Second)

Current IOPS of unaligned read input/output operations per second, addressed at the Target.

Unaligned Read Throughput (Kilobytes per Second)

Current bandwidth of unaligned input/output operations, addressed at the Target.

Unaligned Throughput (Kilobytes per Second)

Current bandwidth of unaligned input/output operations, addressed at the Target.

Unaligned Write IO Rate (Operations per Second)

Current IOPS of unaligned write input/output operations per second, addressed at the Target.

Unaligned Write Throughput (Kilobytes per Second)

Current bandwidth of unaligned write input/output operation, addressed at the Target.

Write IO Rate (Operations per Second)

Total write real-time input/output operations per second.

Write Latency (Microseconds)

Real-time average latency of write operations.

Write Throughput (Kilobytes per Second)

Total write bandwidth in MB per second

X-Brick GUID

The GUID of the X-Brick that this Host Interface is on.

InfiniBand Switch

Name
Description

ADM1024 Sensor Temperature (Celsius)

The temperature of the internal sensor closest to the heat-sink.

ADM1191 Sensor Voltage (Volts)

The voltage of the 12v voltage sensor.

Cluster GUID

GUID for the related Cluster resource.

Enabled State

Indicates whether the InfiniBand Switch is currently enabled or disabled, either by the user or the cluster.

Fan 1 Speed (Rotations per Minute)

The speed of fan 1.

Fan 2 Speed (Rotations per Minute)

The speed of fan 2.

Fan 3 Speed (Rotations per Minute)

The speed of fan 3.

Fan 4 Speed (Rotations per Minute)

The speed of fan 4.

Fan Drawer Status

The fan drawer status, based on the speed of each fan. The fan drawer comprises of four fans. Possible values include 'health', 'one_fan_failed', and 'failed'.

Firmware PSID

Internal ID of the firmware.

Firmware Version

Current firmware version of the InfiniBand Switch.

Firmware Version Error

Used to indicate if the firmware or OS upgrade has failed or is in the process of upgrading. This reflects the aggregate of all Storage Controller OS and firmware upgrades.

FRU Lifecycle State

The FRU state of the InfiniBand Switch, using the generic FRU transition states. Possible values are 'healthy', 'failed', 'disconnected', 'uninitialized', and 'initializing'.

FRU Replace Failure Reason

Reason why the FRU replacement has failed. 'null' means that the last FRU replacement was either not performed for this object or the replacement was successful.

GUID

GUID

Hardware Revision

Hardware level of the InfiniBand Switch.

Identify LED

Indicates whether the identification LED is illuminated for this InfiniBand Switch. The property value is reflected in the GUI LED icon. Note: There is no identification LED in the current PSU. Possible values are 'off', 'blinking', 'on', and 'na'.

Index

The InfiniBand Switch's index number as defined by the XMS upon its creation (a unique positive number).

Inter Switch IB 1 Port State

The status of the first InfiniBand port used to connect to the other InfiniBand Switch.

Inter Switch IB 2 Port State

The status of the second InfiniBand port used to connect to the other InfiniBand Switch.

Is Available

The InfiniBand Switch's availability status in relation to the system.

LM75 Center Sensor Temperature (Celsius)

The temperature of the center temperature sensor close to QSFP cages.

LM75 Left Sensor Temperature (Celsius)

The temperature of the left temperature sensor close to QSFP cages.

LM75 Right Sensor Temperature (Celsius)

The temperature of the right temperature sensor close to QSFP cages.

Object Severity

InfiniBand Switch's severity, based on severity level of current Alerts (Alerts still uncleared) for this resource and its contained objects. Possible values are 'clear', 'information', 'minor', 'major', and 'critical'.

Part Number

EMC-assigned string identifying part (SKU), independent of the actual vendor model_name used for this FRU.

Port Count

Total number of ports in the InfiniBand Switch.

Serial Number

The serial number of the InfiniBand Switch.

Status LED

LED state indicating the InfiniBand Switch's object faults.

SX Internal Sensor Temperature (Celsius)

The temperature of the SwitchX Silicon internal sensor.

Temperature Sensor Count

Total number of temperature sensors.

VCC Sensor Voltage (Volts)

The voltage of the VCC voltage sensor.

VCCP1 Sensor Voltage (Volts)

The voltage of the V-Core voltage sensor.

VCCP2 Sensor Voltage (Volts)

The voltage of the 1.2V voltage sensor.

Voltage for 2.5V Sensor (Volts)

The voltage of the 3.3V SX voltage sensor.

Voltage for 5v Sensor (Volts)

The voltage of the 1.8V voltage sensor.

Voltage Sensor Count

Total number of voltage sensors.

Wrong SC Connection Detected

Denotes if at least one Storage Controller is not connected to the corresponding InfiniBand Switch port.

Local Disk

Name
Description

Bad Sector Count

Number of bad sectors on the local disk.

Cluster GUID

GUID of the cluster the local disk is on.

Disk Failure

Disk failure status of the local disk.

Enabled State

Enabled state of the local disk.

Encryption Status

Encryption status of the local disk.

Expected Type

Local Disk Expected Type

Firmware Version

Firmware version of the local disk.

Firmware Version Error

Firmware version error of the local disk.

FRU Lifecycle State

FRU lifecycle state of the local disk.

FRU Replace Failure Reason

Reason (if any) for the FRU replacement failure.

GUID

GUID of the local disk.

Hardware Revision

Hardware Revision

Identify LED

Identify LED of the local disk.

Index

Index of the local disk.

Model Name

Model Name

Object Severity

Object severity of the local disk.

Part Number

Part number of the local disk.

Purpose

Purpose of the local disk.

Slot Number

Slot number of the local disk.

Status LED

Status LED of the local disk.

Storage Controller GUID

GUID of the storage controller the local disk is on.

Type

Local disk type.

UID

UID of the local disk.

Management Server

Name
Description

128KB Average Latency (Microseconds)

The aggregated latency of 128KB operations for all clusters managed by the XMS.

128KB IO Rate (Operations per Second)

The aggregated value of total read and write real-time input/output operations per second for 128KB operations from all clusters managed by the XMS.

128KB Read IO Rate (Operations per Second)

IO Rate of 128KB read input/output operations from all clusters managed by the XMS.

128KB Read Latency (Microseconds)

XMS's total real-time average latency of 128KB read operations.

128KB Read Throughput (Kilobytes per Second)

The aggregated value of real-time read bandwidth for 128KB operations from all clusters managed by the XMS.

128KB Throughput (Kilobytes per Second)

The aggregated value of total real-time read and write bandwidth of 128KB operations for all clusters managed by the XMS.

128KB Write IO Rate (Operations per Second)

The aggregated value of total write real-time input/output 128KB operations per second from all clusters managed by the XMS.

128KB Write Latency (Microseconds)

Cluster's aggregated value of total real-time average latency of 128KB write operations.

128KB Write Throughput (Kilobytes per Second)

The aggregated value of total real-time write bandwidth of 128KB operations for all clusters managed by the XMS.

16KB Average Latency (Microseconds)

The aggregated latency of 16KB operations for all clusters managed by the XMS.

16KB IO Rate (Operations per Second)

The aggregated value of total read and write real-time input/output operations per second for 16KB operations from all clusters managed by the XMS.

16KB Read IO Rate (Operations per Second)

IO Rate of 16KB read input/output operations from all clusters managed by the XMS.

16KB Read Latency (Microseconds)

XMS's total real-time average latency of 16KB read operations.

16KB Read Throughput (Kilobytes per Second)

The aggregated value of real-time read bandwidth for 16KB operations from all clusters managed by the XMS.

16KB Throughput (Kilobytes per Second)

The aggregated value of total real-time read and write bandwidth of 16KB operations for all clusters managed by the XMS.

16KB Write IO Rate (Operations per Second)

The aggregated value of total write real-time input/output 16KB operations per second from all clusters managed by the XMS.

16KB Write Latency (Microseconds)

Cluster's aggregated value of total real-time average latency of 16KB write operations.

16KB Write Throughput (Kilobytes per Second)

The aggregated value of total real-time write bandwidth of 16KB operations for all clusters managed by the XMS.

1KB Average Latency (Microseconds)

The aggregated latency of 1KB operations for all clusters managed by the XMS.

1KB IO Rate (Operations per Second)

The aggregated value of total read and write real-time input/output operations per second for 1KB operations from all clusters managed by the XMS.

1KB Read IO Rate (Operations per Second)

IO Rate of 1KB read input/output operations from all clusters managed by the XMS.

1KB Read Latency (Microseconds)

XMS's total real-time average latency of 1KB read operations.

1KB Read Throughput (Kilobytes per Second)

The aggregated value of real-time read bandwidth for 1KB operations from all clusters managed by the XMS.

1KB Throughput (Kilobytes per Second)

The aggregated value of total real-time read and write bandwidth of 1KB operations for all clusters managed by the XMS.

1KB Write IO Rate (Operations per Second)

The aggregated value of total write real-time input/output 1KB operations per second from all clusters managed by the XMS.

1KB Write Latency (Microseconds)

Cluster's aggregated value of total real-time average latency of 1KB write operations.

1KB Write Throughput (Kilobytes per Second)

The aggregated value of total real-time write bandwidth of 1KB operations for all clusters managed by the XMS.

1MB Average Latency (Microseconds)

The aggregated latency of 1MB operations for all clusters managed by the XMS.

1MB IO Rate (Operations per Second)

The aggregated value of total read and write real-time input/output operations per second for 1MB operations from all clusters managed by the XMS.

1MB Read IO Rate (Operations per Second)

IO Rate of 1MB read input/output operations from all clusters managed by the XMS.

1MB Read Latency (Microseconds)

XMS's total real-time average latency of 1MB read operations.

1MB Read Throughput (Kilobytes per Second)

The aggregated value of real-time read bandwidth for 1MB operations from all clusters managed by the XMS.

1MB Throughput (Kilobytes per Second)

The aggregated value of total real-time read and write bandwidth of 1MB operations for all clusters managed by the XMS.

1MB Write IO Rate (Operations per Second)

The aggregated value of total write real-time input/output 1MB operations per second from all clusters managed by the XMS.

1MB Write Latency (Microseconds)

Cluster's aggregated value of total real-time average latency of 1MB write operations.

1MB Write Throughput (Kilobytes per Second)

The aggregated value of total real-time write bandwidth of 1MB operations for all clusters managed by the XMS.

256KB Average Latency (Microseconds)

The aggregated latency of 256KB operations for all clusters managed by the XMS.

256KB IO Rate (Operations per Second)

The aggregated value of total read and write real-time input/output operations per second for 256KB operations from all clusters managed by the XMS.

256KB Read IO Rate (Operations per Second)

IO Rate of 256KB read input/output operations from all clusters managed by the XMS.

256KB Read Latency (Microseconds)

XMS's total real-time average latency of 256KB read operations.

256KB Read Throughput (Kilobytes per Second)

The aggregated value of real-time read bandwidth for 256KB operations from all clusters managed by the XMS.

256KB Throughput (Kilobytes per Second)

The aggregated value of total real-time read and write bandwidth of 256KB operations for all clusters managed by the XMS.

256KB Write IO Rate (Operations per Second)

The aggregated value of total write real-time input/output 256KB operations per second from all clusters managed by the XMS.

256KB Write Latency (Microseconds)

Cluster's aggregated value of total real-time average latency of 256KB write operations.

256KB Write Throughput (Kilobytes per Second)

The aggregated value of total real-time write bandwidth of 256KB operations for all clusters managed by the XMS.

2KB Average Latency (Microseconds)

The aggregated latency of 2KB operations for all clusters managed by the XMS.

2KB IO Rate (Operations per Second)

The aggregated value of total read and write real-time input/output operations per second for 2KB operations from all clusters managed by the XMS.

2KB Read IO Rate (Operations per Second)

IO Rate of 2KB read input/output operations from all clusters managed by the XMS.

2KB Read Latency (Microseconds)

XMS's total real-time average latency of 2KB read operations.

2KB Read Throughput (Kilobytes per Second)

The aggregated value of real-time read bandwidth for 2KB operations from all clusters managed by the XMS.

2KB Throughput (Kilobytes per Second)

The aggregated value of total real-time read and write bandwidth of 2KB operations for all clusters managed by the XMS.

2KB Write IO Rate (Operations per Second)

The aggregated value of total write real-time input/output 2KB operations per second from all clusters managed by the XMS.

2KB Write Latency (Microseconds)

Cluster's aggregated value of total real-time average latency of 2KB write operations.

2KB Write Throughput (Kilobytes per Second)

The aggregated value of total real-time write bandwidth of 2KB operations for all clusters managed by the XMS.

32KB Average Latency (Microseconds)

The aggregated latency of 32KB operations for all clusters managed by the XMS.

32KB IO Rate (Operations per Second)

The aggregated value of total read and write real-time input/output operations per second for 32KB operations from all clusters managed by the XMS.

32KB Read IO Rate (Operations per Second)

IO Rate of 32KB read input/output operations from all clusters managed by the XMS.

32KB Read Latency (Microseconds)

XMS's total real-time average latency of 32KB read operations.

32KB Read Throughput (Kilobytes per Second)

The aggregated value of real-time read bandwidth for 32KB operations from all clusters managed by the XMS.

32KB Throughput (Kilobytes per Second)

The aggregated value of total real-time read and write bandwidth of 32KB operations for all clusters managed by the XMS.

32KB Write IO Rate (Operations per Second)

The aggregated value of total write real-time input/output 32KB operations per second from all clusters managed by the XMS.

32KB Write Latency (Microseconds)

Cluster's aggregated value of total real-time average latency of 32KB write operations.

32KB Write Throughput (Kilobytes per Second)

The aggregated value of total real-time write bandwidth of 32KB operations for all clusters managed by the XMS.

4KB Average Latency (Microseconds)

The aggregated latency of 4KB operations for all clusters managed by the XMS.

4KB IO Rate (Operations per Second)

The aggregated value of total read and write real-time input/output operations per second for 4KB operations from all clusters managed by the XMS.

4KB Read IO Rate (Operations per Second)

IO Rate of 4KB read input/output operations from all clusters managed by the XMS.

4KB Read Latency (Microseconds)

XMS's total real-time average latency of 4KB read operations.

4KB Read Throughput (Kilobytes per Second)

The aggregated value of real-time read bandwidth for 4KB operations from all clusters managed by the XMS.

4KB Throughput (Kilobytes per Second)

The aggregated value of total real-time read and write bandwidth of 4KB operations for all clusters managed by the XMS.

4KB Write IO Rate (Operations per Second)

The aggregated value of total write real-time input/output 4KB operations per second from all clusters managed by the XMS.

4KB Write Latency (Microseconds)

Cluster's aggregated value of total real-time average latency of 4KB write operations.

4KB Write Throughput (Kilobytes per Second)

The aggregated value of total real-time write bandwidth of 4KB operations for all clusters managed by the XMS.

512B Average Latency (Microseconds)

The aggregated latency of 512B operations for all clusters managed by the XMS.

512B IO Rate (Operations per Second)

The aggregated value of total read and write real-time input/output operations per second for 512B operations from all clusters managed by the XMS.

512B Read IO Rate (Operations per Second)

IO Rate of 512B read input/output operations from all clusters managed by the XMS.

512B Read Latency (Microseconds)

XMS's total real-time average latency of 512B read operations.

512B Read Throughput (Kilobytes per Second)

The aggregated value of real-time read bandwidth for 512B operations from all clusters managed by the XMS.

512B Throughput (Kilobytes per Second)

The aggregated value of total real-time read and write bandwidth of 512B operations for all clusters managed by the XMS.

512B Write IO Rate (Operations per Second)

The aggregated value of total write real-time input/output 512B operations per second from all clusters managed by the XMS.

512B Write Latency (Microseconds)

Cluster's aggregated value of total real-time average latency of 512B write operations.

512B Write Throughput (Kilobytes per Second)

The aggregated value of total real-time write bandwidth of 512B operations for all clusters managed by the XMS.

512KB Average Latency (Microseconds)

The aggregated latency of 512KB operations for all clusters managed by the XMS.

512KB IO Rate (Operations per Second)

The aggregated value of total read and write real-time input/output operations per second for 512KB operations from all clusters managed by the XMS.

512KB Read IO Rate (Operations per Second)

IO Rate of 512KB read input/output operations from all clusters managed by the XMS.

512KB Read Latency (Microseconds)

XMS's total real-time average latency of 512KB read operations.

512KB Read Throughput (Kilobytes per Second)

The aggregated value of real-time read bandwidth for 512KB operations from all clusters managed by the XMS.

512KB Throughput (Kilobytes per Second)

The aggregated value of total real-time read and write bandwidth of 512KB operations for all clusters managed by the XMS.

512KB Write IO Rate (Operations per Second)

The aggregated value of total write real-time input/output 512KB operations per second from all clusters managed by the XMS.

512KB Write Latency (Microseconds)

Cluster's aggregated value of total real-time average latency of 512KB write operations.

512KB Write Throughput (Kilobytes per Second)

The aggregated value of total real-time write bandwidth of 512KB operations for all clusters managed by the XMS.

64KB Average Latency (Microseconds)

The aggregated latency of 64KB operations for all clusters managed by the XMS.

64KB IO Rate (Operations per Second)

The aggregated value of total read and write real-time input/output operations per second for 64KB operations from all clusters managed by the XMS.

64KB Read IO Rate (Operations per Second)

IO Rate of 64KB read input/output operations from all clusters managed by the XMS.

64KB Read Latency (Microseconds)

XMS's total real-time average latency of 64KB read operations.

64KB Read Throughput (Kilobytes per Second)

The aggregated value of real-time read bandwidth for 64KB operations from all clusters managed by the XMS.

64KB Throughput (Kilobytes per Second)

The aggregated value of total real-time read and write bandwidth of 64KB operations for all clusters managed by the XMS.

64KB Write IO Rate (Operations per Second)

The aggregated value of total write real-time input/output 64KB operations per second from all clusters managed by the XMS.

64KB Write Latency (Microseconds)

Cluster's aggregated value of total real-time average latency of 64KB write operations.

64KB Write Throughput (Kilobytes per Second)

The aggregated value of total real-time write bandwidth of 64KB operations for all clusters managed by the XMS.

8KB Average Latency (Microseconds)

The aggregated latency of 8KB operations for all clusters managed by the XMS.

8KB IO Rate (Operations per Second)

The aggregated value of total read and write real-time input/output operations per second for 8KB operations from all clusters managed by the XMS.

8KB Read IO Rate (Operations per Second)

IO Rate of 8KB read input/output operations from all clusters managed by the XMS.

8KB Read Latency (Microseconds)

XMS's total real-time average latency of 8KB read operations.

8KB Read Throughput (Kilobytes per Second)

The aggregated value of real-time read bandwidth for 8KB operations from all clusters managed by the XMS.

8KB Throughput (Kilobytes per Second)

The aggregated value of total real-time read and write bandwidth of 8KB operations for all clusters managed by the XMS.

8KB Write IO Rate (Operations per Second)

The aggregated value of total write real-time input/output 8KB operations per second from all clusters managed by the XMS.

8KB Write Latency (Microseconds)

Cluster's aggregated value of total real-time average latency of 8KB write operations.

8KB Write Throughput (Kilobytes per Second)

The aggregated value of total real-time write bandwidth of 8KB operations for all clusters managed by the XMS.

Allow Empty Password

Whether or not the user account can have a blank password.

Average Latency (Microseconds)

The aggregated latency for all clusters managed by the XMS.

Average Latency Greater Than 1MB (Microseconds)

The aggregated latency of operations greater than 1MB for all clusters managed by the XMS.

Build

The number of the XMS build.

CPU Utilization (%)

The current XMS's CPU utilization.

Database Version

The version number of the database.

Default User Inactivity Timeout (Minutes)

The XMS's default timeout period. The XMS logs the user out when a timeout period is not set.

Disk Space Secondary Utilization Level

Disk space secondary utilization level. Measures XMS's aggregated value of capacity monitoring.

Disk Space Utilization Level

Monitors the aggregated amount of free disk space on the XMS system for the root partition. An Alert is triggered when the disk utilization of the root portion exceeds the threshold percentage.

Event Log Record Time (Days)

Days in Event Log (the number of days of records that are currently in the log).

Free Disk Space (/root) (Tebibytes)

Aggregated free disk space of the root partition for all clusters managed by the XMS.

Free Disk Space Secondary (Tebibytes)

Aggregated free disk space at the secondary utilization level for all clusters managed by the XMS.

GUID

The GUID of the XMS resource.

Initiator Group Count

The aggregated value of Initator Groups that currently exist in all clusters managed by the XMS.

IO Rate (Operations per Second)

The aggregated value of total read and write real-time input/output operations per second from all clusters managed by the XMS.

IO Rate By Block (Operations per Second)

The aggregated value of total read and write real-time input/output operations per second for Block operations from all clusters managed by the XMS.

IO Rate Greater Than 1MB (Operations per Second)

The aggregated value of total read and write real-time input/output operations per second for operations greater than 1MB from all clusters managed by the XMS.

IP Version

The IP version used by the XMS for both southbound (towards clusters) and northbound.

ISCSI Route Count

The aggregated amount of iSCSI routes for all clusters managed by the XMS.

Logical Space In Use (Tebibytes)

Aggregated used logical disk space for all clusters managed by the XMS.

Logs Size (Gibibytes)

The aggregated log size of all clusters managed by the XMS.

Management Interface

The physical network interface used by the XMS to communicate with the clusters.

Maximum Records In Event Log

The aggregated value of maximum records in the Event Logs of all clusters managed by the XMS.

Memory Utilization Level

Monitors the aggregated free memory on all clusters managed by the XMS.

Mode

Determines whether NTP is automatically or manually configured.

Object Severity

The XMS's severity, based on severity level of current Alerts (Alerts still uncleared) for this XMS. Possible values are 'clear', 'information', 'minor', 'major', and 'critical'.

Overall Efficiency Ratio (%)

The aggregated value of the ratio of provisioned Volume capacity to the cluster's actual used physical capacity.

RAM Free (Gibibytes)

Aggregated free memory for all clusters managed by the XMS.

RAM Total (Gibibytes)

Total available RAM for all clusters managed by the XMS.

RAM Usage (Gibibytes)

RAM usage for all clusters managed by the XMS.

Read IO Rate (Operations per Second)

IO Rate of read input/output operations from all clusters managed by the XMS.

Read IO Rate By Block (Operations per Second)

The aggregated value of Block input/output per second handled by all clusters managed by the XMS.

Read IO Rate Greater Than 1MB (Operations per Second)

IO Rate of read input/output operations greater than 1MB from all clusters managed by the XMS.

Read Latency (Microseconds)

XMS's total real-time average latency of read operations.

Read Latency Greater Than 1MB (Microseconds)

XMS's total real-time average latency of read operations greater than 1MB.

Read Throughput (Kilobytes per Second)

The aggregated value of real-time read bandwidth from all clusters managed by the XMS.

Read Throughput By Block (Kilobytes per Second)

The aggregated value of real-time read bandwidth for Block operations from all clusters managed by the XMS.

Read Throughput Greater Than 1MB (Kilobytes per Second)

The aggregated value of real-time read bandwidth for operations greater than 1MB from all clusters managed by the XMS.

Read / Write Ratio

The ratio of read to write IOPS.

REST API Protocol Version

Exposes the supported RESTful API version.

Server Name

The fully qualified name of the XMS server.

Software Version

XMS software version. This version should be identical to the cluster's software version, unless it is undergoing a special process (e.g. upgrade).

System Count

The number of clusters managed by the XMS.

Thin Provisioning Savings (%)

The aggregated value of percentage of Volume capacity not in use.

Throughput (Kilobytes per Second)

The aggregated value of total real-time read and write bandwidth for all clusters managed by the XMS.

Throughput By Block (Kilobytes per Second)

The aggregated value of total real-time read and write bandwidth of Block operations for all clusters managed by the XMS.

Throughput Greater Than 1MB (Kilobytes per Second)

The aggregated value of total real-time read and write bandwidth of operations greater than 1MB for all clusters managed by the XMS.

Uptime

The amount of time passed since the XMS was last rebooted.

Used Memory (Gibibytes)

Memory in use.

User Account Count

The number of user accounts associated with the XMS.

Version

The installed XtremIO XMS version.

Volume Count

Number of volumes for all clusters managed by the XMS.

Write IO Rate (Operations per Second)

The aggregated value of total write real-time input/output operations per second from all clusters managed by the XMS.

Write IO Rate By Block (Operations per Second)

The aggregated value of input/output per second handled by all clusters managed by the XMS.

Write IO Rate Greater Than 1MB (Operations per Second)

The aggregated value of total write real-time input/output operations greater than 1MB per second from all clusters managed by the XMS.

Write Latency (Microseconds)

Cluster's aggregated value of total real-time average latency of write operations.

Write Latency Greater Than 1MB (Microseconds)

Cluster's aggregated value of total real-time average latency of write operations greater than 1MB.

Write Throughput (Kilobytes per Second)

The aggregated value of total real-time write bandwidth of all clusters managed by the XMS.

Write Throughput By Block (Kilobytes per Second)

The aggregated value of current bandwidth for all clusters managed by the XMS, used to get a Snapshot of the aggregated totals by block size.

Write Throughput Greater Than 1MB (Kilobytes per Second)

The aggregated value of total real-time write bandwidth of operations greater than 1MB for all clusters managed by the XMS.

Wrong CN In CSR

Triggers an Alert if the default CSR (Certificate Signing Request) contains CN which is not the XMS's FQDN.

XMS Gateway

XMS's default gateway IP address.

XMS IP

IP address of the XMS.

XMS IP Subnet

XMS IP address and subnet mask. The XMS IP address is optional. It is not required if this command is only used to update the Storage Controller's IP or IPMI addresses.

PSU

Name
Description

Cluster GUID

GUID of the PSU's cluster.

DAE GUID

GUID of the PSU's DAE.

Enabled State

Enabled State

Firmware Version

Firmware Version

Firmware Version Error

Firmware Version Error

FRU Lifecycle State

FRU Lifecycle State

FRU Replace Failure Reason

FRU Replace Failure Reason

GUID

GUID of the PSU.

Hardware Revision

Hardware Revision

Identification

Identification

Identify LED

Identify LED

Index

Index

Input

Input

Location

Location

Model Name

Model Name

Object Severity

Object Severity

Part Number

Part Number

Power Failure

Power Failure

Power Feed

Power Feed

Serial Number

Serial Number

Status LED

Status LED of the PSU.

Storage Controller GUID

GUID of the PSU's Storage Controller.

X-Brick GUID

GUID of the PSU's X-Brick.

Snapshot

Name
Description

Accumulated Read Operation Count (Operations)

Total accumulative number of read operations having occurred during the Volume's lifespan.

Accumulated Size of Read (Tebibytes)

Accumulative capacity KB size of read operations having occurred during the Snapshot's lifespan.

Accumulated Size of Write (Tebibytes)

Accumulative capacity size of write operations having occurred during the Snapshot's lifespan.

Accumulated Small Read Operation Count (Operations)

Accumulated number of small reads input/output operations for the Snapshot.

Accumulated Small Write Operation Count (Operations)

Accumulated number of small writes input/output operations recursively contained by this Snapshot

Accumulated Unaligned Read Operation Count (Operations)

Snapshot's accumulated number of I/Os since adding the Initiator.

Accumulated Unaligned Write Operation Count (Operations)

Cluster's total number of accumulated unaligned writes.

Accumulated Write Operation Count (Operations)

Accumulative number of write operations having occurred during the Snapshot's lifespan.

Alignment Offset

The alignment offset range is between 0-15.

Average Latency (Microseconds)

Total real-time average latency of read and write operations.

Certainty

Indicates confidence that the XMS and the cluster are synchronized. Value changes from OK if a request is sent while the XMS is unable to determine the success of the request.

Cluster GUID

GUID for the related Cluster resource.

Created From Volume

This parameter contains the snapped_object Volume name, as it was at the Snapshot's creation time, or null when the Volume was not created from a Snapshot. The string remains unchanged when the ancestor is renamed, deleted or reassigned.

Creation Time

Snapshot's creation timestamp.

Destination Snapshot Count

Number of Snapshots directly Snapshotted from this Snapshot.

GUID

GUID

Index

Snapshot's index number as defined by the XMS upon its creation (a unique positive number).

IO Rate (Operations per Second)

Snapshot 's total read and write real-time input/output operations per second.

Lb Size

The 'sector size' (LB size) of the Snapshot.

Logical Space In Use

The total used Volume/ Snapshot capacity in all clusters managed by the XMS.

LUN Mapping Count

Number of LUN mappings defined for this Snapshot.

NAA Name

Snapshot's WWN/NAA name, globally unique and unique over time, set by the XMS (or by cluster) once a LUN is mapped to the Snapshot for the first time.

Object Severity

Snapshot's severity, based on severity level of current Alerts (Alerts still uncleared) for this Snapshot. Possible values are 'clear', 'information', 'minor', 'major', and 'critical'.

Read IO Rate (Operations per Second)

Total read real-time input/output operations per second.

Read Latency (Microseconds)

Total real-time average latency of read operations.

Read Throughput (Kilobytes per Second)

Total real-time read bandwidth in MB per second.

Small IO Alerts

When Volume parameter of small_io_alerts is set to 'disabled' (default), no Alerts are sent for a high number of small I/Os.

Small IO Rate (Operations per Second)

Current IO Rate of small input/output operations per second.

Small IO Ratio (%)

The accumulated number of unaligned I/O divided by the total accumulated number of I/Os to the Snapshot.

Small IO Ratio Level

Event triggered whenever the unaligned-io-ratio level changes.

Small Read IO Rate (Operations per Second)

Current IO Rate of small read input/output operations per second.

Small Read Throughput (Kilobytes per Second)

Current bandwidth of small input/output operations, addressed at the Snapshot.

Small Throughput (Kilobytes per Second)

Current bandwidth of small input/output operations, addressed at the Snapshot.

Small Write IO Rate (Operations per Second)

Current IO Rate of small write input/output operations per second.

Small Write Throughput (Kilobytes per Second)

Snapshot's small write bandwidth.

Throughput (Kilobytes per Second)

Total real-time read and write bandwidth in MB per second.

Type

A Snapshot is regular (default) or readonly.

Unaligned IO Alerts

When this Snapshot parameter is set to disabled (default), no Alerts are sent for high numbers of unaligned.

Unaligned IO Rate (Operations per Second)

Unaligned input/output operations per second.

Unaligned IO Ratio (%)

Accumulated number of unaligned I/O divided by the total accumulated number of I/Os to the Snapshot.

Unaligned IO Ratio Level

Event triggered whenever the unaligned-io-ratio level changes.

Unaligned Read IO Rate (Operations per Second)

Current IO Rate of unaligned read input/output operations per second.

Unaligned Read Throughput (Kilobytes per Second)

Current bandwidth of unaligned read input/output operations.

Unaligned Throughput (Kilobytes per Second)

Current IO Rate of unaligned bandwidth input/output operations.

Unaligned Write IO Rate (Operations per Second)

Current IO Rate of unaligned write input/output operations per second.

Unaligned Write Throughput (Kilobytes per Second)

Current bandwidth of unaligned write input/output operations

VAAI Thin Provisioning Alerts

The VAAI Soft Limit warning for this Volume is reported when monitoring is enabled. The threshold is a cluster-wide value as configured in the cluster vaai_tp_limit. The default is disabled.

Volume Access

Denotes the host access configuration. Possible values are 'no_access', 'read_access', or 'writes_access'.

Volume Size (Tebibytes)

Total provisioned capacity. Snapshot KB size as exposed to Initiators.

Volume Snapshot Source Index Number

Holds the Volume Snapshot source index number for the Snapshot. This parameter points to an object from which the Snapshot was created, providing that the 'ancestor' object is not deleted, or that create-snapshot-and-reassign was not applied.

Volume Snapshot Source Name

Name of the parent Volume of this Snapshot. This parameter points to an object from which the Snapshot was created, providing that the 'ancestor' object is not deleted, or that create-snapshot-and-reassign was not applied.

Volume Type

Denotes the Volume type. Possible values are 'regular' or 'readonly'.

Write IO Rate (Operations per Second)

Total write real-time input/output operations per second.

Write Latency (Microseconds)

Total real-time average latency of write operations.

Write Throughput (Kilobytes per Second)

Total real-time write bandwidth in MB per second

XMS GUID

GUID for the related XtremIO Management Server resource.

SSD

Name
Description

Bad Sector Count

Number of bad sectors, detected in the SSD

Certainty

XMS Certaintity. Indicates confidence that XMS and the cluster are synchronized

Cluster GUID

GUID of the cluster containing the SSD.

Data Protection Group GUID

GUID of the Data Protection Group the SSD belongs to.

Diagnostic Health State

Reflects the health of the SSD device itself

DPG State

Displays the state of the SSD related to the DPG to which it belongs.

Enabled State

Indicates whether the SSD is currently enabled or disabled, either by the user or the cluster

Encryption Status

SSD's encryption (Data at Rest) status

Endurance Remaining (%)

Percentage of SSD endurance remaining

Failure Reason

SSD Failure Reason

Firmware Version

Current firmware version of the SSD

Firmware Version Error

Reason for FRU diagnostic failure when a firmware problem exists

FRU Lifecycle State

SSD's FRU state, using the generic FRU transition states

GUID

GUID

Hardware Revision

Hardware level of power supply unit

Health State

The SSD's state of health

Identify LED

Indicates whether the identification LED is illuminated for ths SSD. The property value is reflected in the GUI LED icon

Index

Index

IO Error ASC

The ASC code of the most recent I/O error

IO Error ASCQ

The ASCQ code of the most recent I/O error

IO Error Sense Code

The sense code of an I/O error

IO Error Vendor Specific

Vendor specific information string of the most recent I/O error

IO Rate (Operations per Second)

SSD IO Rate

Last IO Error Timestamp

Timestamp of the last recorded I/O error

Last IO Error Type

The last IO Error Type

Link 1 Health State

Reflects the SSD health state. Relates to the first port, which should be connected to Storage Controller-1.

Link 2 Health State

Reflects the SSD health state. Relates to the first port, which should be connected to Storage Controller-2.

Model Name

Vendor's assigned SSD model name

Object Severity

SSD's severity, based on severity level of current Alerts (Alerts still uncleared) for this SSD

Part Number

A string assigned by EMC identifying the part

Percent Endurance Remaining Level

Percent Endurance Remaining Level

Read IO Rate (Operations per Second)

Read IO Rate

Read Throughput (Kilobytes per Second)

Read Throughput

Read / Write Ratio

The ratio of read to write IOPS.

Serial Number

Serial Number

Size (Gibibytes)

The overall size of the SSD

Slot Number

Slot index in which SSD currently resides, or Slot index into which the currently-disconnected SSD was previously inserted

Smart Error ASC

The ASC code of the most recent SMART error (two hex digits)

Smart Error ASCQ

The ASCQ code of the most recent SMART error (two hex digits)

Space In Use (Gibibytes)

SSD Space In Use

Status LED

LED state, indicating SSD object faults

Swap LED

Defines whether a replacement procedure is to be activated when a new SSD is inserted into the DAE.

Throughput (Kilobytes per Second)

Throughput of the SSD

UID

UID (unique identification) of the SSD that is inserted into the Slot.

Useful SSD Space (Gibibytes)

The useful size of this specific SSD

Write IO Rate (Operations per Second)

Write IO Rate for SSD

Write Throughput (Kilobytes per Second)

Write Throughput of the SSD

X-Brick GUID

GUID of the X-Brick containing the SSD

Storage Controller

Name
Description

Active IPMI Port

The port which is currently being used for IPMI.

Backend Storage Controller State

The state of the backend Storage Controller.

BIOS Firmware Version

The BIOS firmware version of the storage controller.

Cluster GUID

GUID of the storage controller's cluster.

Current Health State

The current health state of the Storage Controller.

DAE Controller Discovery Needed

Whether or not the cluster has detected new DAE controllers.

DAE Discovery Needed

Whether or not DAE discovery is needed.

DAE PSU Discovery Needed

Whether or not the cluster has detected a new DAE PSU.

Data Protection Group GUID

GUID of the storage controller's data protection group.

Dedicated IPMI Link Connection State

The state of the link between the dedicated IPMI port and the other Storage Controller.

Dedicated IPMI Port Speed

Negotiated speed of the dedicated IPMI port.

Dedicated IPMI Port State

The state of the dedicated Ethernet port used for IPMI access.

DIMM Correctable Errors (Errors)

The number of DIMM ECC correctable errors.

DIMM Health State

The health state of the DIMM.

Enabled State

Indicates whether the Storage Controller is currently enabled or disabled, either by user or the cluster.

Fan Health State

The health state of the least healthy fan, based on both analog and discrete sensors.

FC HBA Hardware Revision

Detected Fibre Channel host bus adaptors hardware revision.

FC HBA Model

Fibre Channel host bus adaptors hardware model.

Firmware Version Error

Whether or not the firmware or OS upgrade has failed or is in the process of upgrading.

FRU Lifecycle State

The Storage Controller's FRU state, using the generic FRU transition states.

GUID

GUID of the storage controller.

IB 1 Link Downed

The total number of times this port was declared 'down'.

IB 1 Link Downed Over Last Five Minutes

The number of times InfiniBand port 1 was declared 'down' over the past five minutes.

IB 1 Link Downed Over Last Minute

The number of times InfiniBand port 1 was declared 'down' in the past minute.

IB 1 Link Error Recoveries

The number of times this InfiniBand port successfully completed a link error recovery procedure.

IB 1 Link Error Recoveries Over Last Five Minutes

The number of link error recoveries by InfiniBand port 1 over the past five minutes.

IB 1 Link Error Recoveries Over Last Minute

The number of link error recoveries for InfiniBand port 1 over the past minute.

IB 1 Link Health Level

The most severe problem detected on InfiniBand port 1.

IB 1 Link Rate In Gbps

The link rate of InfiniBand port 1.

IB 1 Local Link Integrity Errors (Errors)

The total number of local link integrity errors encountered by InfiniBand port 1.

IB 1 Local Link Integrity Errors Over Last Five Minutes (Errors)

The number of local link integrity errors encountered by InfiniBand port 1 over the past five minutes.

IB 1 Local Link Integrity Errors Over Last Minute (Errors)

The number of local link integrity errors encountered by InfiniBand port 1 over the past minute.

IB 1 Peer OID

The object index number of the specific peer object connected to the storage controller.

IB 1 Port In Peer Index

Index of the port within the storage controller this port is connected to (0 if the port is unconnected). The value is meaningful only when port_peer_type is not none.

IB 1 Port Misconnection

Whether or not a problem exists in InfiniBand port 1.

IB 1 Port Peer Type

Defines whether port 1 is connected to a storage controller, another switch, or is disconnected.

IB 1 Port Received Errors (Errors)

The total number of received errors encountered by InfiniBand port 1.

IB 1 Port Received Errors Over Last Five Minutes (Errors)

The number of received errors encountered by InfiniBand port 1 over the past five minutes.

IB 1 Port Received Errors Over Last Minute (Errors)

The number of received errors encountered by InfiniBand port 1 over the past minute.

IB 1 Port Received Remote Physical Errors (Errors)

The total number of received remote physical errors encountered by InfiniBand port 1.

IB 1 Port Received Remote Physical Errors Over Last Five Minutes (Errors)

The number of received remote physical errors over the past five minutes by InfiniBand port 1.

IB 1 Port Received Remote Physical Errors Over Last Minute (Errors)

Number of packets received on this InfiniBand port with errors over the past minute.

IB 1 Port State

The state of the Storage Controller's InfiniBand port 1.

IB 1 Symbol Errors (Errors)

The total number of symbol errors encountered by InfiniBand port 1.

IB 1 Symbol Errors Over Last Five Minutes (Errors)

The number of symbol errors encountered by InfiniBand port 1 over the past minute.

IB 1 Symbol Errors Over Last Minute (Errors)

The number of symbol errors encountered by InfiniBand port 1 in the past minute.

IB 2 Link Downed

The total number of times InfiniBand port 2 was declared 'down'.

IB 2 Link Downed Over Last Five Minutes

The number of times InfiniBand port 2 was declared 'down' over the past five minutes.

IB 2 Link Downed Over Last Minute

The number of times this InfiniBand port was marked as 'down' over the past minute.

IB 2 Link Error Recoveries

Number of times this InfiniBand port successfully completed a link error recovery procedure.

IB 2 Link Error Recoveries Over Last Five Minutes

The number of link error recoveries by InfiniBand port 2 over the past five minutes.

IB 2 Link Error Recoveries Over Last Minute

The number of link error recoveries by InfiniBand port 2 over the past minute.

IB 2 Link Health Level

The most severe problem detected over this InfiniBand link.

IB 2 Link Rate In Gbps

The InfiniBand link rate for port 2.

IB 2 Local Link Integrity Errors (Errors)

The total number of local link integrity errors encountered by InfiniBand port 2.

IB 2 Local Link Integrity Errors Over Last Five Minutes (Errors)

The number of local link integrity errors this InfiniBand port has encountered over the past five minutes.

IB 2 Local Link Integrity Errors Over Last Minute (Errors)

Number of local link integrity errors encountered by InfiniBand port 2 over the past minute.

IB 2 Peer OID

The object index number of the specific peer object connected to the storage controller.

IB 2 Port In Peer Index

Index of the port within the storage controller this port is connected to (0 if the port is unconnected). The value is meaningful only when port_peer_type is not none.

IB 2 Port Misconnection

Whether or not there is a connection problem between the Storage Controller and InfiniBand port 2.

IB 2 Port Peer Type

Defines whether port 2 is connected to a storage controller, another switch, or is disconnected.

IB 2 Port Received Errors (Errors)

Number of packets received with errors by InfiniBand port 2.

IB 2 Port Received Errors Over Last Five Minutes (Errors)

The number of packets received with error by InfiniBand port 2 over the past five minutes.

IB 2 Port Received Errors Over Last Minute (Errors)

Number of packets received on this InfiniBand port with errors over the past minute.

IB 2 Port Received Remote Physical Errors (Errors)

Total number of received remote physical errors encountered by InfiniBand port 2.

IB 2 Port Received Remote Physical Errors in the Last 5 Minutes (Errors)

The number of remote physical errors this InfiniBand port has encountered over the past five minutes.

IB 2 Port Received Remote Physical Errors Over Last Minute (Errors)

The number of remote physical errors encountered by the InfiniBand port.

IB 2 Port State

State of the InfiniBand port 2.

IB 2 Symbol Errors (Errors)

Total number of symbol errors on this InfiniBand port.

IB 2 Symbol Errors Over Last Five Minutes (Errors)

The number of symbol errors this InfiniBand port has encountered over the past five minutes.

IB 2 Symbol Errors Over Last Minute (Errors)

The number of symbol errors on this InfiniBand port in the past minute.

IB Address 1

Storage controller's internal backend InfiniBand addresses for port 1.

IB Address 2

Storage controller's internal backend InfiniBand addresses for port 2.

IB Switch PSU Discovery Needed

Whether or not the cluster has detected a new InfiniBand PSU.

IB Switches Discovery Needed

Whether or not the cluster has detected new InfiniBand switches.

Identify LED

Whether or not the identification LED is illuminated for the Storage Controller.

Index

The index of the storage controller.

Index In Brick

Index in brick.

Internal Sensor Health State

Reflects health state of the least healthy of all temperature/voltage/fan/current/internal sensor types. Value is based on both the analog and discrete sensors of each type.

IPMI Address

IPMI address and subnet for the storage controller.

IPMI Address Subnet

Subnet of the IPMI's address.

IPMI BMC Firmware Version

The firmware version of the IPMI.

IPMI BMC Hardware Revision

The hardware revision of the IPMI.

IPMI BMC Model

The hardware model of the IPMI.

IPMI Connection Error Reason

The reason for the disconnection from the Storage Controller's IPMI.

IPMI Gateway IP

The IPMI default gateway's IP address.

Is SYM Node

Indicates if this storage controller is the storage controller running the SYM.

ISCSI Daemon State

The state of the ISCSI daemon.

Journal State

The state of the Storage Controller's journal.

Local Disk Controller Firmware Version

Storage controller's current firmware version.

Local Disk Controller Hardware Revision

Revision for the local disk storage storage controller hardware.

Local Disk Count

Number of local disks for the storage controller.

Local Disk Discovery Needed

Whether or not the cluster has detected a new local disk.

Low Ram Level

The value from the Storage Controller's 'RAM Level Low' indicator.

Management Gateway IP

The IPMI default gateway's IP management.

Management Link Health Level

The Storage Controller's management port health state.

Management Port Auto-Negotiation

Indicates if auto-negotiation is enabled (default) or disabled.

Management Port Duplex

Ethernet port duplex. The current port configuration applies if the port is full duplex or half duplex.

Management Port Speed

Management port speed.

Management Port State

The Storage Controller's managment port state.

Monitored UPS Count

Number of BBUs that are connected to the storage controller.

Node CSID

Internal storage controller naming index number.

Node Front Panel Temperature State

The temperature sensor reading for above normal temperatures.

Node GUID

GUID (Globally Unique Identifier) hardwired in the physical storage controller.

Node Health State

Health state of the Storage Controller and its components.

Node Index

Node index.

Node Journaling Health State

The health state of the journaling component.

Node Manager Address

The IP addresses used to access the storage controller manager.

Node Manager Address Subnet

The storage controller's subnet mask management IP.

Node Manager Connection Error Reason

Reason for the last disconnection between the XMS and the Storage Controller.

Node Manager Connection State

The state of the connection between XMS and Storage Controller manager.

Node PSU Count

Storage controller's number of storage controller PSU objects and the list of their object IDs. There should be two PSUs per storage controller.

Node PSU Discovery Needed

Whether or not the cluster has detected a new Storage Controller PSU.

Node Stop Reason

The reason reported for the Storage Controller stoppage.

Node Stop Type

The type of the most recent stop.

Object Severity

Object severity of the storage controller.

OS Upgrade Current Step

The current step of the OS upgrade.

OS Upgrade Current Step Info

Information about the current step of the OS upgrade (if any).

OS Version

Storage Controller operating system version, equivalent to the firmware for other components.

PCI 10GE HBA Firmware Version

iSCSI host bus adaptors firmware version.

PCI 10GE HBA Hardware Revision

iSCSI host bus adaptors hardware revision.

PCI 10GE HBA Model

iSCSI host bus adaptors model name.

PCI Disk Controller Firmware Version

DAE controller's firmware version.

PCI Disk Controller Hardware Revision

DAE controller's hardware revision.

PCI IB HBA Firmware Version

InfiniBand host bus adaptors firmware revision.

PCI IB HBA Hardware Revision

InfiniBand host bus adaptors hardware revision.

PCI IB HBA Model

Infiniband host bus adaptors hardware model.

Remote Journal Health State

The health state of the remote journal.

SAS 1 HBA Port Health Level

The health level of the Storage Controller's SAS port 1.

SAS 1 Port Rate

Rate of the first serial attached SCSI (SAS) port used.

SAS 1 Port State

The state of the first SAS port used.

SAS 2 HBA Port Health Level

The health level of the Storage Controller's SAS port 2.

SAS 2 Port Rate

Rate of the second serial attached SCSI (SAS) port used.

SAS 2 Port State

The state of the SAS port 2.

SC DAE Access State

DAE access state of the Storage Controller.

SC Start Timestamp

The last time this storage controller was started.

SC Start Timestamp Display

The storage controller's last start time.

Serial Number

The serial number of the storage controller.

Software Version

Software version.

SSD Count

The total number of SSDs in this storage controller's X-Brick.

SSD Discovery Needed

Whether or not the cluster has detected a new SSD.

Status LED

Status LED.

Targets Discovery Needed

Whether or not the cluster has detected new targets.

Temperature Health State

The health state of the least healthy temperature sensor, based on both analog and discrete sensors.

Upgrade Failure Reason

The reason for the failed upgrade (if any).

Upgrade State

The state of the last upgrade process for the Storage Controller.

UPS Discovery Needed

Whether or not BBU discovery is needed.

Voltage Health State

The aggregated health state of the voltage sensors.

X-Brick GUID

GUID of the storage controller's X-Brick.

Volume

Name
Description

Access

Denotes the type of volume and its accessibility.

Accumulated Read Operation Count

Total accumulative number of read operations having occurred during the Volume's lifespan

Accumulated Size of Read (Gigabytes)

Accumulative capacity KB size of read operations having occurred during the Volume's lifespan

Accumulated Size of Write (Gigabytes)

Accumulative capacity KB size of write operations having occurred during the Volume's lifespan

Accumulated Small Read Operation Count

Accumulated number of small reads input/output operations of the Volume

Accumulated Small Write Operation Count

Accumulated number of small writes input/output operations recursively contained by this Volume

Accumulated Unaligned Read Operation Count

Volume's accumulated number of I/Os since adding an Initiator.

Accumulated Unaligned Write Operation Count

Cluster's total number of accumulated unaligned writes

Accumulated Write Operation Count

Accumulative number of write operations having occurred during the Volume's lifespan

Alignment Offset

The alignment offset range(between 0-15).

Average Latency (Microseconds)

Average Latency

Certainty

Indicates confidence that the XMS and the cluster are synchronized. The value changes from OK if a request is sent while the XMS is unable to determine the success of the request.

Cluster GUID

The GUID of the cluster containing the volume.

Created From Volume

This parameter contains the snapped_object Volume name, as it was at the Snapshot's creation time, or null when the Volume was not created from a Snapshot. The string remains unchanged when the ancestor is renamed, deleted or reassigned.

Destination Snapshot Count

Number of Volumes directly Snapshotted from this Volume

GUID

The GUID of the volume.

Index

Volume's index number as defined by the XMS upon its creation (a unique positive number)

IO Rate (Operations per Second)

IO Rate

LB Size

The "sector size" (LB size) of the Volume

Logical Space In Use (Tebibytes)

Logical Space In Use

LUN Mapping Count

Number of LUN mappings defined for this Volume

NAA Name

Volume's WWN/NAA name, globally unique and unique over time, set by the XMS (or by cluster) once a LUN is mapped to the Volume for the first time

Object Severity

Volume's severity, based on severity level of current Alerts (Alerts still uncleared) for this Volume

Read IO Rate (Operations per Second)

Read IO Rate

Read Latency (Microseconds)

Read Latency

Read Throughput (Kilobytes per Second)

Read Throughput

Read / Write Ratio

The ratio of read to write IOPS.

Size (Tebibytes)

Total provisioned capacity. Volume KB size as exposed to Initiators

Small IO Rate (Operations per Second)

Small IO Rate

Small IO Ratio

Small IO Ratio

Small IO Ratio Level

Event triggered whenever the unaligned-io-ratio level changes

Small Read IO Rate (Operations per Second)

Small Read IO Rate

Small Read Throughput (Kilobytes per Second)

Small Read Throughput

Small Throughput (Kilobytes per Second)

Small Throughput

Small Write IO Rate (Operations per Second)

Small Write IO Rate

Small Write Throughput (Kilobytes per Second)

Small Write Throughput

Snapshot Group ID

The Volume Snapshot Group (VSG) Index

Snapshot Source Index Number

Holds the Volume Snapshot source index number for the Snapshot. This parameter points to an object from which the Snapshot was created, providing that the 'ancestor' object is not deleted, or that create-snapshot-and-reassign was not applied.

Snapshot Type

The Snapshot is regular (default) or readonly.

Throughput (Kilobytes per Second)

Throughput

Type

Denotes the Volume type. Values: [regular or readonly]

Unaligned IO Alerts

When this Volume parameter is set to disabled (default), no Alerts are sent for a high number of unaligned I/Os.

Unaligned IO Rate (Operations per Second)

Unaligned IO Rate

Unaligned IO Ratio

Unaligned IO Ratio

Unaligned IO Ratio Level

Event triggered whenever the unaligned-io-ratio level changes

Unaligned Read IO Rate (Operations per Second)

Unaligned Read IO Rate

Unaligned Read Throughput (Kilobytes per Second)

Unaligned Read Throughput

Unaligned Throughput (Kilobytes per Second)

Unaligned Throughput

Unaligned Write IO Rate (Operations per Second)

Unaligned Write IO Rate

Unaligned Write Throughput (Kilobytes per Second)

Unaligned Write Throughput

VAAI Thin Provisioning Alerts

The VAAI Soft Limit warning for this Volume is reported when monitoring is enabled. The threshold is a cluster-wide value as configured in the cluster vaai_tp_limit. The default is disabled.

Write IO Rate (Operations per Second)

Write IO Rate

Write Latency (Microseconds)

Write Latency

Write Throughput (Kilobytes per Second)

Write Throughput

X-Brick

Name
Description

Brick State

X-Brick's current state

Cluster GUID

The index number of the cluster this X-Brick belongs to. Maybe omitted if only one cluster is defined.

GUID

GUID

Index

The X-Brick index number as defined by the XtremIO Management Server upon its creation (a unique positive number).

Index In System

The X-Brick's index.

Object Severity

X-Brick severity, based on severity level of current Alerts (Alerts still uncleared) for this X-Brick. Possible values are 'clear', 'information', 'minor', 'major', and 'critical'.

SSD Count

The X-Brick's total number of SSDs.

Storage Controller Count

X-Brick's total number of Storage Controllers.