Dell EMC Compute

Monitor Dell EMC Compute Blade, Rack, VXRail, and Chassis

❗️

This source has been deprecated

observIQ is in the process of transitioning a subset of BindPlane's monitoring capabilities to the observIQ OpenTelemetry Collector. As a result, this Source is no longer publicly available in BindPlane. If you need access to this Source, please reach out to our support via chat or via [email protected].

Data Collection Setup

Monitor the configuration, power consumption, and other metrics in your Dell EMC Compute Environment.

Metrics are collected via SNMP calls to each Dell Server via iDrac and Blade Server Chassis via CMC.

🚧

SNMP v3 Required for Alerts

In order to retrieve alerts that are triggered directly by iDRAC/SNMP, the adapter instance must use SNMP v3.

SNMP Service Configuration Examples:

The below examples show enabling the SNMP Network Services for both CMC and iDrac. Note your interface may be different based on server Generation.

1263

CMC SNMP Service Configuration Example

979

Dell iDrac SNMP Configuration Example

Network Requirements

Port: 161 (UDP) SNMP connection to each iDrac and CMC interface

Least Privileged User

  • SNMP v2, v2c: community string to give read-only permissions.
  • SNMP v3: requires a least-privileged SNMP user account of read-only.

Supported Versions

Hardware:
R-, M-, and T-series generation Dell EMC server types:

  • 12g
  • 13g
  • 14g

📘

VXRAIL Hardware Support

VXRail, Dell Generation Hardware is supported

Software:
iDrac Servers must be equipped with iDRAC v7+ with firmware version 1.30.30+.
(Where iDRAC v7 is the generation)

CMC firmware 5.0+
Note: M1000e, VTRX, and VXRail CMC configurations are supported

Management IP Definition Methods

BindPlane supports the following host formats:

  • Individual hostname or IP address (IPv4/IPv6 are supported)
  • IP range (e.g., 192.168.0.32-192.168.0.67, 10.10.01.0-10.10.0.254)

📘

If the SNMP IP range is greater than 400 IP addresses, Test Connection may fail.

  • IP CIDR notation range (e.g., 10.6.14.0/24, 2620:0:2d0:200:1f00:400::7/120)
  • Any of the above in a comma-separated list

📘

If the IP range for your Chassis Monitoring Console (CMC) is different than that of your iDRAC, you must list it separately here to return chassis metrics.

Connection Parameters

NameRequired?Description
SNMP Version
Management IPRequiredSee above "Management IP Definition Methods" Examples
SNMP Port
Community StringRequired
UserRequired
Context
Security Level
Authentication TypeRequired
Auth PasswordRequired
Privacy TypeRequired
Privacy PasswordRequired
Retries
Timeout IntervalTimeout in seconds before a confirmed request is resent or timed out.
Socket Timeout IntervalThe socket timeout for incoming messages in seconds. A timeout of zero is interpreted as an infinite timeout.
Discovery Timeout IntervalThe amount of time in seconds that we should allow discovery to take against a given target.
Collection Timeout IntervalThe amount of time in seconds that we should allow collection to take against a given target.
Model
Max Threads
Include SNMP Alerts
Alert Cancel Hours

Metrics

Amperage Probe

NameDescription
Chassis IndexThe Chassis Index of the Amperage Probe.
IndexThe Index of the Amperage Probe.
LocationThe Location of the Amperage Probe.
Power Supply (Amperes)The Power Supply of the Amperage Probe.
Power Supply Power (Watts)The Power Supply Power of the Amperage Probe.
Probe Current (Milliamperes)The Power Supply Power of the Amperage Probe.
Server Current (Amperes)The Server Amperage of the Amperage Probe.
Server Power (Watts)The Server Power of the Amperage Probe.
Service TagThe Service Tag of the Amperage Probe.
StatusThe Status of the Amperage Probe.
TypeType

Blade Server

NameDescription
Amperage Probe Relatives in Healthy State (%)The percentage of relatives of type amperage_probe whose status doesn't warrant creating an event.
Amperage ProbesThe Amperage Probes of the Blade Server.
Average Memory Device Size (Gibibytes)The Average Memory Device Size of the Blade Server.
Average Memory Device Speed (Megahertz)The Average Memory Device Speed of the Blade Server.
Average Physical Disk Available RAID (Mebibytes)The Average Physical Disk Available RAID of the Blade Server.
Average Physical Disk Capacity (Mebibytes)The Average Physical Disk Capacity of the Blade Server.
Average Physical Disk Used RAID (Mebibytes)The Average Physical Disk Used RAID of the Blade Server.
Average Processor Speed (Megahertz)The Average Processor Device Current Speed of the Blade Server.
Average Processor Voltage (Millivolts)The Average Processor Device Voltage of the Blade Server.
Average Server Current (Amperes)The Average Server Amperage of the Blade Server.
Average Server Power (Watts)The Average Server Power of the Blade Server.
Average Temperature Probe Reading (Celsius)The Average Temperature Probe Reading of the Blade Server.
Average Virtual Disk Capacity (Mebibytes)The Average Virtual Disk Capacity of the Blade Server.
Blade Slot NumberThe Blade Slot Number of the Blade Server.
Express Service CodeThe Express Service Code of the Blade Server.
Form FactorThe Form Factor of the Blade Server.
FQDNThe FQDN of the Blade Server.
Global Storage StatusThe Storage Status of the Blade Server.
Global Server StatusThe Global Server Status of the Blade Server.
Highest Memory Device Size (Gibibytes)The Largest Memory Device Size of the Blade Server.
Highest Memory Device Speed (Megahertz)The Fastest Memory Device Speed of the Blade Server.
Highest Physical Disk Available RAID (Mebibytes)The Largest Physical Disk Available RAID of the Blade Server.
Highest Physical Disk Capacity (Mebibytes)The Largest Physical Disk Capacity of the Blade Server.
Highest Physical Disk Used RAID (Mebibytes)The Largest Physical Disk Used RAID of the Blade Server.
Highest Processor Speed (Megahertz)The Fastest Processor Device Current Speed of the Blade Server.
Highest Processor Voltage (Millivolts)The Highest Processor Device Voltage of the Blade Server.
Highest Server Current (Amperes)The Highest Server Amperage of the Blade Server.
Highest Server Power (Watts)The Highest Server Power of the Blade Server.
Highest Temperature Probe Reading (Celsius)The Highest Temperature Probe Reading of the Blade Server.
Highest Virtual Disk Capacity (Mebibytes)The Largest Virtual Disk Capacity of the Blade Server.
IDThe ID of the Blade Server.
LCD StatusThe LCD Status of the Blade Server.
Lowest Memory Device Size (Gibibytes)The Smallest Memory Device Size of the Blade Server.
Lowest Memory Device Speed (Megahertz)The Slowest Memory Device Speed of the Blade Server.
Lowest Physical Disk Available RAID (Mebibytes)The Smallest Physical Disk Available RAID of the Blade Server.
Lowest Physical Disk Capacity (Mebibytes)The Smallest Physical Disk Capacity of the Blade Server.
Lowest Physical Disk Used RAID (Mebibytes)The Smallest Physical Disk Used RAID of the Blade Server.
Lowest Processor Speed (Megahertz)The Slowest Processor Device Current Speed of the Blade Server.
Lowest Processor Voltage (Millivolts)The Lowest Processor Device Voltage of the Blade Server.
Lowest Server Current (Amperes)The Lowest Server Amperage of the Blade Server.
Lowest Server Power (Watts)The Lowest Server Power of the Blade Server.
Lowest Temperature Probe Reading (Celsius)The Lowest Temperature Probe Reading of the Blade Server.
Lowest Virtual Disk Capacity (Mebibytes)The Smallest Virtual Disk Capacity of the Blade Server.
MAC AddressesThe MAC Addresses of the Blade Server.
Management IPThe Management IP of the Blade Server.
Memory Device Relatives in Healthy State (%)The percentage of relatives of type memory_device whose status doesn't warrant creating an event.
Memory DevicesThe Memory Devices of the Blade Server.
Model NameThe Model Name of the Blade Server.
Operating System NameThe OS Name of the Blade Server.
Physical Disk Relatives in Healthy State (%)The percentage of relatives of type physical_disk whose status doesn't warrant creating an event.
Physical DisksThe Physical Disks of the Blade Server.
Power StateThe Power State of the Blade Server.
Processor Device Relatives in Healthy State (%)The percentage of relatives of type processor_device whose status doesn't warrant creating an event.
Processor DevicesThe Processor Devices of the Blade Server.
RAC DescriptionThe RAC Description of the Blade Server.
RAC Firmware VersionThe RAC Firmware Version of the Blade Server.
RAC ManufacturerThe RAC Manufacturer of the Blade Server.
RAC NameThe RAC Name of the Blade Server.
RAC TypeThe RAC Type of the Blade Server.
RAC URLThe RAC URL of the Blade Server.
RAC VersionThe RAC Version of the Blade Server.
Rack SlotThe Rack Slot of the Blade Server.
Service TagThe Service Tag of the Blade Server.
State SettingsThe State Settings of the Blade Server.
StatusThe Status of the Blade Server.
System BatteriesThe System Batteries of the Blade Server.
System Battery Relatives in Healthy State (%)The percentage of relatives of type system_battery whose status doesn't warrant creating an event.
Temperature Probe Relatives in Healthy State (%)The percentage of relatives of type temperature_probe whose status doesn't warrant creating an event.
Temperature ProbesThe Temperature Probes of the Blade Server.
Total Memory Device Size (Gibibytes)The Total Memory Device Size of the Blade Server.
Total Physical Disk Available RAID (Mebibytes)The Total Physical Disk Available RAID of the Blade Server.
Total Physical Disk Capacity (Mebibytes)The Total Physical Disk Capacity of the Blade Server.
Total Physical Disk Used RAID (Mebibytes)The Total Physical Disk Used RAID of the Blade Server.
Total Processor CoresThe Total Processor Device Core Count of the Blade Server.
Total Server Current (Amperes)The Total Server Amperage of the total_processorServer.
Total Server Power (Watts)The Total Server Power of the Blade Server.
Total Virtual Disk Capacity (Mebibytes)The Total Virtual Disk Capacity of the Blade Server.
VersionThe Version of the Blade Server.
Virtual Disk Relatives in Healthy State (%)The percentage of relatives of type virtual_disk whose status doesn't warrant creating an event.
Virtual DisksThe Virtual Disks of the Blade Server.
Voltage Probe Relatives in Healthy State (%)The percentage of relatives of type voltage_probe whose status doesn't warrant creating an event.
Voltage ProbesThe Voltage Probes of the Blade Server.

Chassis

NameDescription
Blade Server Service TagsThe Blade Server Service Tags of the Chassis.
Blade Server Slot NamesThe Blade Server Slot Names of the Chassis.
Blade StatusThe Blade Status of the Chassis.
Service TagThe Service Tag of the Chassis.
CMC Card Temperature (Celsius)The CMC Card Temperature of the Chassis.
CMC Processor Temperature (Celsius)The CMC Processor Temperature of the Chassis.
CMC StatusThe CMC Status of the Chassis.
Cumulative Power Usage (Kilowatt-Hours)The Cumulative Power Usage of the Chassis.
Express Service CodeThe Express Service Code of the Chassis.
Fan StatusThe Fan Status of the Chassis.
Front Panel Temperature (Celsius)The Front Panel Temperature of the Chassis.
iKVM StatusThe iKVM Status of the Chassis.
Idle Power (Watts)The Idle Power of the Chassis.
Instantaneous Current Usage (Amperes)The Instantaneous Current Usage of the Chassis.
Instantaneous Power Usage (Watts)The Instantaneous Power Usage of the Chassis.
IOM StatusThe IOM Status of the Chassis.
Last Minimum Usage ResetThe Last Minimum Usage Reset of the Chassis.
Last Peak Usage ResetThe Last Peak Usage Reset of the Chassis.
Last Power Usage ResetThe Last Power Usage Reset of the Chassis.
LocationThe Location of the Chassis.
Management IPThe Management IP of the Chassis.
Maximum Power Specification (Watts)The Maximum Power Specification of the Chassis.
Minimum Usage (Watts)The Minimum Usage of the Chassis.
ModelThe Model of the Chassis.
NameThe Name of the Chassis.
Peak Usage (Watts)The Peak Usage of the Chassis.
Potential Power (Watts)The Potential Power of the Chassis.
Power StatusThe Power Status of the Chassis.
Power SuppliesThe Power Supplies of the Chassis.
Power Surplus (Watts)The Power Surplus of the Chassis.
Redundancy StatusThe Redundancy Status of the Chassis.
Size (Rack Unit)The Size of the Chassis.
StatusThe Status of the Chassis.
System IDThe System ID of the Chassis.
Temperature StatusThe Temperature Status of the Chassis.

Chassis Power Supply

NameDescription
Chassis IndexThe Chassis Index of the Chassis Power Supply.
Service TagThe Service Tag of the Chassis Power Supply.
Current (Amperes)The Amps Reading of the Chassis Power Supply.
IndexThe Index of the Chassis Power Supply.
LocationThe Location of the Chassis Power Supply.
Monitoring CapableThe Monitoring Capable of the Chassis Power Supply.
Power (Watts)The Watts Reading of the Chassis Power Supply.
Voltage (Volts)The Volts Reading of the Chassis Power Supply.

Cooling Device

NameDescription
Chassis IndexThe Chassis Index of the Cooling Device.
IndexThe Index of the Cooling Device.
Is Turned OnThe Is Turned On of the Cooling Device.
LocationThe Location of the Cooling Device.
NameThe Name of the Cooling Device.
Service TagThe Service Tag of the Cooling Device.
Speed (Rotations per Minute)The Speed of the Cooling Device.
StatusThe Status of the Cooling Device.
TypeThe Type of the Cooling Device.

Intrusion Probe

NameDescription
Chassis IndexThe Chassis Index of the Intrusion Probe.
IndexThe Index of the Intrusion Probe.
LocationThe Location of the Intrusion Probe.
ReadingThe Reading of the Intrusion Probe.
Service TagThe Service Tag of the Intrusion Probe.
State CapabilitiesThe State Capabilities of the Intrusion Probe.
State SettingsThe State Settings of the Intrusion Probe.
StatusThe Status of the Intrusion Probe.
TypeThe Type of the Intrusion Probe.

Memory Device

NameDescription
Chassis IndexThe Chassis Index of the Memory Device.
IndexThe Index of the Memory Device.
LocationThe Location of the Memory Device.
Part NumberThe Part Number of the Memory Device.
Serial NumberThe Serial Number of the Memory Device.
Service TagThe Service Tag of the Memory Device.
Size (Gibibytes)The Size of the Memory Device.
Speed (Megahertz)The Speed of the Memory Device.
StatusThe Memory Device Status of the Memory Device.

Physical Disk

NameDescription
Available RAID Disk Space (Mebibytes)The Available RAID Disk Space of the Physical Disk.
Capacity (Mebibytes)The Capacity of the Physical Disk.
Fully Qualified Device DescriptorThe Fully Qualified Device Descriptor of the Physical Disk.
Media TypeThe Media Type of the Physical Disk.
NumberThe Number of the Physical Disk.
Operational StateThe Physical Disk Operational State of the Physical Disk.
Part NumberThe Part Number of the Physical Disk.
Power StateThe Physical Disk Power State of the Physical Disk.
Security StatusThe Physical Security Disk State of the Physical Disk.
Serial NumberThe Serial Number of the Physical Disk.
Service TagThe Service Tag of the Physical Disk.
StateThe Physical Disk State of the Physical Disk.
Used RAID Disk Space (Mebibytes)The Used RAID Disk Space of the Physical Disk.

Power Unit

NameDescription
Average Output Power (Watts)The Average Output Power of the Power Unit.
Average Rated Input Power (Watts)The Average Rated Input Power of the Power Unit.
Chassis IndexThe Chassis Index of the Power Unit.
Count For RedundancyThe Count For Redundancy of the Power Unit.
Highest Input Voltage (Volts)The Highest Input Voltage of the Power Unit.
Highest Output Power (Watts)The Highest Output Power of the Power Unit.
Highest Rated Input Power (Watts)The Highest Rated Input Power of the Power Unit.
IndexThe Index of the Power Unit.
Lowest Input Voltage (Volts)The Lowest Input Voltage of the Power Unit.
Lowest Output Power (Watts)The Lowest Output Power of the Power Unit.
Lowest Rated Input Power (Watts)The Lowest Rated Input Power of the Power Unit.
NameThe Name of the Power Unit.
Service TagThe Service Tag of the Power Unit.
StatusThe Power Unit Status of the Power Unit.
Total Input Voltage (Volts)The Total Input Voltage of the Power Unit.
Total Output Power (Watts)The Total Output Power of the Power Unit.
Total Rated Input Power (Watts)The Total Rated Input Power of the Power Unit.

Processor Device

NameDescription
BrandThe Brand Name of the Processor Device.
Chassis IndexThe Chassis Index of the Processor Device.
CoresThe Cores of the Processor Device.
Cores EnabledThe Cores Enabled of the Processor Device.
Current Speed (Megahertz)The Current Speed of the Processor Device.
IndexThe Index of the Processor Device.
ManufacturerThe Manufacturer of the Processor Device.
Service TagThe Service Tag of the Processor Device.
StatusThe Processor Device Status of the Processor Device.
Status StateThe Processor Device Status State of the Processor Device.
ThreadsThe Threads of the Processor Device.
VersionThe Version of the Processor Device.
Voltage (Millivolts)The Voltage of the Processor Device.

Rack Power Supply

NameDescription
Chassis IndexThe Chassis Index of the Rack Power Supply.
IndexThe Index of the Rack Power Supply.
Input Voltage (Volts)The Input Voltage of the Rack Power Supply.
Output Power (Watts)The Output Power of the Rack Power Supply.
Power Unit Index ReferenceThe Power Unit Index Reference of the Rack Power Supply.
Rated Input Power (Watts)The Rated Input Power of the Rack Power Supply.
Sensor StateThe Power Supply Sensor State of the Rack Power Supply.
Service TagThe Service Tag of the Rack Power Supply.
State Settings UniqueThe Power Supply State Settings Unique of the Rack Power Supply.
StatusThe Power Supply Status of the Rack Power Supply.

Rack Server

NameDescription
Amperage Probe Relatives in Healthy State (%)The percentage of relatives of type amperage_probe whose status doesn't warrant creating an event.
Amperage ProbesThe Amperage Probes of the Rack Server.
Average Memory Device Size (Gibibytes)The Average Memory Device Size of the Rack Server.
Average Memory Device Speed (Megahertz)The Average Memory Device Speed of the Rack Server.
Average Physical Disk Available RAID (Mebibytes)The Average Physical Disk Available RAID of the Rack Server.
Average Physical Disk Capacity (Mebibytes)The Average Physical Disk Capacity of the Rack Server.
Average Physical Disk Used RAID (Mebibytes)The Average Physical Disk Used RAID of the Rack Server.
Average Power Supply (Amperes)The Average Power Supply of the Rack Server.
Average Processor Speed (Megahertz)The Average Processor Device Current Speed of the Rack Server.
Average Processor Voltage (Millivolts)The Average Processor Device Voltage of the Rack Server.
Average Server Power (Watts)The Average Server Power of the Rack Server.
Average Temperature Probe Reading (Celsius)The Average Temperature Probe Reading of the Rack Server.
Average Voltage Probe Reading (Millivolts)The Average Voltage Probe Reading of the Rack Server.
Cooling Device Relatives in Healthy State (%)The percentage of relatives of type cooling_device whose status doesn't warrant creating an event.
Cooling DevicesThe Cooling Devices of the Rack Server.
Express Service CodeThe Express Service Code of the Rack Server.
Form FactorThe Form Factor of the Rack Server.
FQDNThe FQDN of the Rack Server.
global Storage StatusThe Storage Status of the Rack Server.
Global Server StatusThe Global Server Status of the Rack Server.
Highest Memory Device Size (Gibibytes)The Largest Memory Device Size of the Rack Server.
Highest Memory Device Speed (Megahertz)The Fastest Memory Device Speed of the Rack Server.
Highest Physical Disk Available RAID (Mebibytes)The Largest Physical Disk Available RAID of the Rack Server.
Highest Physical Disk Capacity (Mebibytes)The Largest Physical Disk Capacity of the Rack Server.
Highest Physical Disk Used RAID (Mebibytes)The Largest Physical Disk Used RAID of the Rack Server.
Highest Power Supply (Amperes)The Highest Power Supply of the Rack Server.
Highest Processor Speed (Megahertz)The Fastest Processor Device Current Speed of the Rack Server.
Highest Processor Voltage (Millivolts)The Highest Processor Device Voltage of the Rack Server.
Highest Server Power (Watts)The Highest Server Power of the Rack Server.
Highest Temperature Probe Reading (Celsius)The Highest Temperature Probe Reading of the Rack Server.
Highest Voltage Probe Reading (Millivolts)The Highest Voltage Probe Reading of the Rack Server.
IDThe ID of the Rack Server.
Intrusion Probe Relatives in Healthy State (%)The percentage of relatives of type intrusion_probe whose status doesn't warrant creating an event.
Intrusion ProbesThe Intrusion Probes of the Rack Server.
LCD StatusThe LCD Status of the Rack Server.
Lowest Memory Device Size (Gibibytes)The Smallest Memory Device Size of the Rack Server.
Lowest Memory Device Speed (Megahertz)The Slowest Memory Device Speed of the Rack Server.
Lowest Physical Disk Available RAID (Mebibytes)The Smallest Physical Disk Available RAID of the Rack Server.
Lowest Physical Disk Capacity (Mebibytes)The Smallest Physical Disk Capacity of the Rack Server.
Lowest Physical Disk Used RAID (Mebibytes)The Smallest Physical Disk Used RAID of the Rack Server.
Lowest Power Supply (Amperes)The Lowest Power Supply of the Rack Server.
Lowest Processor Speed (Megahertz)The Slowest Processor Device Current Speed of the Rack Server.
Lowest Processor Voltage (Millivolts)The Lowest Processor Device Voltage of the Rack Server.
Lowest Server Power (Watts)The Lowest Server Power of the Rack Server.
Lowest Temperature Probe Reading (Celsius)The Lowest Temperature Probe Reading of the Rack Server.
Lowest Voltage Probe Reading (Millivolts)The Lowest Voltage Probe Reading of the Rack Server.
MAC AddressesThe MAC Addresses of the Rack Server.
Management IPThe Management IP of the Rack Server.
Memory Device Relatives in Healthy State (%)The percentage of relatives of type memory_device whose status doesn't warrant creating an event.
Memory DevicesThe Memory Devices of the Rack Server.
Model NameThe Model Name of the Rack Server.
Operating System NameThe OS Name of the Rack Server.
OS VersionThe OS Version of the Rack Server.
Physical Disk Relatives in Healthy State (%)The percentage of relatives of type physical_disk whose status doesn't warrant creating an event.
Physical DisksThe Physical Disks of the Rack Server.
Power StateThe Power State of the Rack Server.
Power Unit Relatives in Healthy State (%)The percentage of relatives of type power_unit whose status doesn't warrant creating an event.
Power UnitsThe Power Units of the Rack Server.
Processor Device Relatives in Healthy State (%)The percentage of relatives of type processor_device whose status doesn't warrant creating an event.
Processor DevicesThe Processor Devices of the Rack Server.
RAC DescriptionThe RAC Description of the Rack Server.
RAC Firmware VersionThe RAC Firmware Version of the Rack Server.
RAC ManufacturerThe RAC Manufacturer of the Rack Server.
RAC NameThe RAC Name of the Rack Server.
RAC TypeThe RAC Type of the Blade Server.
RAC URLThe RAC URL of the Rack Server.
RAC VersionThe RAC Version of the Rack Server.
Rack Power Supply Relatives in Healthy State (%)The percentage of relatives of type rack_power_supply whose status doesn't warrant creating an event.
Rack SlotThe Rack Slot of the Rack Server.
Service TagThe Service Tag of the Rack Server.
State SettingsThe State Settings of the Rack Server.
StatusThe Status of the Rack Server.
System BatteriesThe System Batteries of the Rack Server.
System Battery Relatives in Healthy State (%)The percentage of relatives of type system_battery whose status doesn't warrant creating an event.
Temperature Probe Relatives in Healthy State (%)The percentage of relatives of type temperature_probe whose status doesn't warrant creating an event.
Temperature ProbesThe Temperature Probes of the Rack Server.
Total Memory Device Size (Gibibytes)The Total Memory Device Size of the Rack Server.
Total Physical Disk Available RAID (Mebibytes)The Total Physical Disk Available RAID of the Rack Server.
Total Physical Disk Capacity (Mebibytes)The Total Physical Disk Capacity of the Rack Server.
Total Physical Disk Used RAID (Mebibytes)The Total Physical Disk Used RAID of the Rack Server.
Total Power Supply (Amperes)The Total Power Supply of the Rack Server.
Total Processor CoresThe Total Processor Device Core Count of the Rack Server.
Total Server Power (Watts)The Total Server Power of the total_processorServer.
VersionThe Version of the Rack Server.
Voltage Probe Relatives in Healthy State (%)The percentage of relatives of type voltage_probe whose status doesn't warrant creating an event.
Voltage ProbesThe Voltage Probes of the Rack Server.

System Battery

NameDescription
Chassis IndexThe Chassis Index of the Server Battery.
IndexThe Index of the Server Battery.
Server Battery ReadingThe Server Battery Reading of the Server Battery.
Server Battery StatusThe Server Battery Status of the Server Battery.
Service TagThe Service Tag of the Server Battery.

Temperature Probe

NameDescription
Chassis IndexThe Chassis Index of the Temperature Probe.
IndexThe Index of the Temperature Probe.
LocationThe Location of the Temperature Probe.
Reading (Celsius)The Reading of the Temperature Probe.
Service TagThe Service Tag of the Temperature Probe.
StatusThe Status of the Temperature Probe.

Virtual Disk

NameDescription
Available ProtocolsThe Available Protocols of the Virtual Disk.
Bad Blocks Detected (Blocks)The Bad Blocks Detected of the Virtual Disk.
Cache PolicyThe Cache Policy of the Virtual Disk.
Capacity (Mebibytes)The Virtual Disk Capacity of the Virtual Disk.
Component StatusThe Component Status of the Virtual Disk.
Fully Qualified Device DescriptorThe Fully Qualified Device Descriptor of the Virtual Disk.
LayoutThe Layout of the Virtual Disk.
Media TypeThe Media Type of the Virtual Disk.
NameThe Name of the Virtual Disk.
NumberThe Number of the Virtual Disk.
Operational StateThe Operational State of the Virtual Disk.
ProgressThe Progress of the Virtual Disk.
Read PolicyThe Read Policy of the Virtual Disk.
Remaining RedundancyThe Remaining Redundancy of the Virtual Disk.
Service TagThe Service Tag of the Virtual Disk.
StateThe Virtual Disk State of the Virtual Disk.
Stripe SizeThe Stripe Size of the Virtual Disk.
Write PolicyThe Write Policy of the Virtual Disk.

Voltage Probe

NameDescription
Chassis IndexThe Chassis Index of the Voltage Probe.
Discrete ReadingThe Discrete Reading of the Voltage Probe.
IndexThe Index of the Voltage Probe.
LocationThe Location of the Voltage Probe.
ReadingThe Reading of the Voltage Probe.
Service TagThe Service Tag of the Voltage Probe.